Aim. To assess the diagnostic value of standard and modified ultrasound criteria for left ventricular noncompaction (LVNC).Material and methods. The study included 37 patients. All patients underwent echocardiography and magnetic resonance imaging (MRI). Patients with any of the standard echocardiographic criteria for LVNC (Chin, Jenni, Stollberger) were included in the study. We studied modified echocardiographic criteria of LVNC in 4 and 3-chamber apical views in systole and diastole in the anterolateral (ALsist and ALdiast) and posterolateral (PLsist and PLdiast) walls with the non-compact to compact layer ratio (NC/C) >2. To assess the diagnostic value of the echocardiographic LVNC criteria, the specificity (SP) and sensitivity (SN), the likelihood ratio for positive (LR+) and negative (LR-) test results were calculated, and the operating characteristic curve (ROC) was analyzed.Results. The study included 19 women (51,4%) and 18 men (48,6%), aged 18 to 69 years. The mean age of the patients was 37,7±12,6 years. Relative to the Petersen's MRI-criterion for the Chin's criterion, SN was 55%, SP — 53% (LR+ =1,2, LR- =0,9); for the Jenni's criterion, SN — 55%, SP — 35% (LR+ =0,9, LR- =1,3); for the Stollberger's criterion, SN — 70%, SP — 18% (LR+ =0,9, LR- =1,7); for PLsyst criterion, SP — 82%, SN — 50% (LR+ =2,8, LR- =0,6). Relative to the Grothoff's MRI-criterion, which determined the LVNC mass as a percentage, for the Chin's criterion, SN was 69%, SP — 58% (LR+ =of 1,7, LR- =0,5); for the Jenni's criterion, SN — 85%, SP — 54% (LR+ =1,9, LR- =0,3); for the Stollberger's criterion, SN — 77%, SP — 25% (LR+ =1,0, LR- =0,9); for PLdiast criterion SP — 79%, SN — 62% (LR+ =3,0, LR- =0,5); for PLsyst criterion SP — 63%, SN — 84% (LR+ of 2,2, LR- =0,3); for ALdiast criterion, SP — 83%, SN — 69% (LR+ =4,1, LR- =0,4); for ALsyst criterion, SP — 71%, SN — 92% (LR+ =3,1, LR- =0,1). Relative to the Grothoff's MRI-criterion, which determined the LVNC mass index, for the Chin's criterion, SN was 59%, SP — 70% (LR+ =2,0, LR- =0,6); for the Jenni's criterion, SN — 67%, SP — 60% (LR+ =1,7, LR- =0,6); for the Stollberger's criterion SN — 78%, SP — 30% (LR+ =1,1, LR- =0,7); for the PLdiast criterion, SN — 33%, SP — 60% (LR+ =0,7, LR- =1,3); for PLsist criterion, SN — 59%, SP — 60% (LR+ =1,5, LR- =0,7); for ALdiast criterion, SN — 41%, SP — 80% (LR+ =2,0, LR- =0,7); for ALsist criterion, SN — 67%, SP — 90% (LR+ =6,7, LR- =0,4). Using ROC analysis with NC/C ratio of 2,3 for the ALsyst criterion, SN was 62%, SP — 92%; with NC/C ratio of 2,2 for PLsyst criteria in a posterolateral view in systole, SN — 62%, SP — 83%; with NC/C ratio of 2,1 for ALdiast criterion in an anterolateral view in diastole, SN — 54%, SP — 88%; with NC/C ratio of 2,1 for PLdiast criterion in a posterolateral view in diastole, SN — 46%, SP — 96%.Conclusion. Standard echocardiographic criteria are characterized by moderate sensitivity and low specificity. To improve the diagnostic accuracy of LVNC, the combined use of modified echocardiographic criteria is possible. As a screening of LVNC, using NC/C of 2,2 for the PLsist and NC/C of 2,3 for the PLsist to improve the specificity of the study should be useful.

Publisher

Silicea - Poligraf, LLC

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3