DX single-lead implantable cardioverter-defibrillator system with a floating atrial dipole: when, to whom, and why?

Author:

Prokopenko A. V.1ORCID,Ivanitsky E. A.1ORCID

Affiliation:

1. Federal Center for Cardiovascular Surgery

Abstract

The article reflects information for cardiologists, cardiac surgeons, doctors pro­gramming implanted antiarrhythmic devices, employees and residents of the depart­ments of cardiology and cardiac surgery. Most often, we choose a model of an implantable cardioverter-defibrillator (ICD) strictly individually for each patient, based on the anamnesis characteristics, safety and highest efficiency of ICD systems offered on the market. With each new ICD model, manufacturing companies strive to minimize the number of implantable components and develop better algorithms to discriminate between atrial tachyarrhythmias and true ventricular tachyarrhythmias. However, the risk of inappropriate ICD therapy still remains high. Thus, attending physicians and cardiologists programming implantable antiarrhythmic devices often face difficulties in correcting ICD settings and planning further treatment of a patient with shocks caused by atrial tachyarrhythmias. The authors sought to form an idea about the features of a single-chamber ICD recording atrial potentials using a floating dipole, as well as the advantages of the DX system over classical single-chamber ICD systems, and to define a type of a patient for whom this implantable system would be the best choice preventing sudden cardiac death.

Publisher

Silicea - Poligraf, LLC

Subject

Cardiology and Cardiovascular Medicine

Reference27 articles.

1. Priori S, Blomström-Lundqvist C, Mazzanti A, et al. 2015 ESC Guidelines for the mana­gement of patients with ventricular arrhythmias and the prevention of sudden cardiac death. Eur Heart J. 2015;36(41):2793-867. doi:10.1093/eurheartj/ehv316.

2. McMurray J, Adamopoulos S, Anker SD, et al. ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure 2012: The Task Force for the Diagnosis and Treatment of Acute and Chronic Heart Failure 2012 of the European Society of Cardiology. Developed in collaboration with the Heart Failure Association (HFA) of the ESC. Eur Heart J. 2012;33(14):1787-847. doi:10.1093/eurheartj/ehs10.

3. Kutyifa V, Daubert JP, Olshansky B, et al. Characterization and predictors of first and subsequent inappropriate ICD therapy by heart rate ranges: Result of the MADIT-RIT efficacy analysis. Heart Rhythm. 2015;12(9):2030-37. doi:10.1016/j.hrthm.2015.05.021.

4. Leenhardt A, Defaye P, Mouton E, et al. OPERA Registry Investigators. First inappro­priate implantable cardioverter defibrillator therapy is often due to inaccurate device programming: analysis of the French OPERA registry. Europace. 2012;14(10):1465-74. doi:10.1093/europace/eus144.

5. Berenbom LD, Weiford BC, Vacek JL, et al. Differences in outcomes between patients treated with single- versus dual-chamber implantable cardioverter defibrillators: a substudy of the Multicenter Automatic Defibrillator Implantation Trial II. Ann Noninvasive Electrocardiol. 2005;10(4):429-35. doi:10.1111/j.1542-474X.2005.00063.x.