A new approach in cardioverter-defibrillator implantation in patients with coronary artery disease

Author:

Atabekov Т. A.1ORCID,Batalov R. E.1ORCID,Krivolapov S. N.1ORCID,Sazonova S. I.1ORCID,Khlynyn M. S.1ORCID,Levintas A. D.1ORCID,Popov S. V.1ORCID

Affiliation:

1. Tomsk National Research Medical Center

Abstract

Aim.Defibrillation lead implantation technique optimization using cardiac scintigraphy in patients with coronary artery disease (CAD).Material and methods.In this study 81 patients (male — 72, age 64,0±8,7 years with CAD and indications for the cardioverter-defibrillator (ICD) implantation were examined. Patients were divided into two groups. In 1-st group before ICD implantation, patients underwent cardiac 99mTc-methoxy-isobutyl-isonitrile scintigraphy for right ventricle wall perfusion disorders assessment. In this group defibrillating lead was implanted to the septal position, if the perfusion disorders were in the apical segments, and to the apical position, if perfusion disorders were in the septal segment. In 2-nd group lead was implanted using conventional approach. Defibrillating lead parameters (threshold, sense, impedance and shock impedance on 1-st, 7-th, 30-th and 180-th follow-up days) were compared.Results.The 1-st group consisted of 45 (55,5%) patients (male — 41, age 62,2±8,8 years). In 28 (62,2%) cases in this group defibrillating lead was implanted to the apical and in 17 (37,8%) — to the septal position. The 2-nd group consisted of 36 (44,5%) patients (male — 31, age 66,3±8,2 years; p=0,03). In 20 (55,5%) cases in this group defibrillating lead was implanted to the septal and in 16 (44,5%) — to the apical position. There were significant differences between groups in terms of: threshold and sense at all follow-up days (p=0,0001) and impedance on 1-st (p=0,003), 30-th (p=0,0001) and 180-th day (p=0,002), respectively.Conclusion.Assessment of right ventricular perfusion before ICD implantation can reduce threshold and raise sense, thereby prolong the ICD longevity and improve life-threatening ventricular tachyarrhythmia detection in the early and long-term period in patients with CAD.

Publisher

Silicea - Poligraf, LLC

Subject

Cardiology and Cardiovascular Medicine

Reference26 articles.

1. 1. Epstein AE, DiMarco JP, Ellenbogen KA, et al. ACC/AHA/HRS, 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines. Journal of the American College of Cardiology. 2008;51

2. 10.1016/j.jacc.2008.02.032

3. 10.1111/j.1540-8159.2012.03407.x

4. Beau S, Greer S, Ellis CR, et al. Performance of an ICD algorithm to detect lead noise and reduce inappropriate shocks. J Interv Card Electrophysiol. 2016;45(2):225-32. doi:10.1007/s10840-015-0081-6.

5. 10.1111/j.1540-8159.2007.00730.x