Comparative analysis of prothrombotic activity in patients with myocardial infarction with and without obstructive coronary artery disease

Author:

Vorobieva D. A.1ORCID,Lugacheva Yu. G.1ORCID,Kapilevich N. A.1ORCID,Ryabov V. V.2ORCID

Affiliation:

1. Cardiology Research Institute, Tomsk National Research Medical Center

2. Cardiology Research Institute, Tomsk National Research Medical Center; Siberian State Medical University

Abstract

Aim. To compare parameters of prothrombotic activity in patients with myocardial infarction (MI) with obstructive (MICAD) and non-obstructive coronary artery disease (MINOCA).Material and methods. The study included 40 patients with MI, which were divided into experimental (n=19) and control group (n=21). Three patients (15,7%) with acute myocarditis were excluded from the analysis. Hemostasiological and hematological blood tests were studied upon admission, on the 2nd, 4th, 7th days from hospitalization. Blood samples for protein C, antithrombin, von Willebrand factor (VWF), plasminogen, homocysteine were performed on 4th±1 day from hospitalization. To determine the IgG/IgM anticardiolipin (aCL) and anti-beta 2 glycoprotein I (β2-GPI) antibodies in order to diagnose antiphospholipid syndrome (APS), the ORGENTEC Anti- β2-Glycoprotein I IgG/IgM ELISA enzyme immunoassay was used. Blood tests for lupus anticoagulant were performed using an ACL-Top 700 analyzer (Werfen) with HemosIL SynthASil dRVVT screen/dRVVT confirm and with a SCT screen/SCT confirm quartz activator.Results. According to the data obtained, it was found that patients with MINOCA had a significantly lower level of plasminogen (p=0,007), as well as a higher level of homocysteine (p=0,03). For such indicators as protein C, antithrombin, ejection fraction, differences between the groups were not revealed (p<0,05). At the same time, protein C deficiency was detected in 2 (12,5%) patients with MINOCA and in 1 (5,3%) patient in the control group. Antithrombin deficiency was detected in 2 (12,5%) patients with MINOCA and in 2 (9,5%) patients with MICAD. An increase in the level of ejection fraction was found in 6 (37,5%) patients in the study group and in 7 (33,3%) patients in the control group. There were no differences in levels of lupus anticoagulant, aCL and β2-GPI antibodies (p>0,05). There was a higher platelet count in patients with MINOCA on the 2nd and 4th days of acute MI (p=0,46 and p=0,01, respectively). However, the hemoglobin level in patients with MINOCA was significantly lower on admission, 4th and 7th day of MI (p=0,02, p=0,03 and p=0,04, respectively).Conclusion. According to the study results, in patients with MINOCA and MICAD, differences in blood thrombotic activity were revealed. A higher level of homocysteine and a lower level of plasminogen were determined in patients with MINOCA. For such parameters as protein C, antithrombin, VWF, aCL and β2-GPI antibodies, differences between the groups were not determined. According to laboratory data, patients with MINOCA showed higher platelet count, but lower levels of hemoglobin and hematocrit in the early postinfarction period.

Publisher

Silicea - Poligraf, LLC

Subject

Cardiology and Cardiovascular Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3