Aim. Implantable cardioverter­defibrillator (ICD) implantation technique optimization in patients with coronary artery disease (CAD) in order to reduce fluoroscopy time and total radiation dose to staff.Material and methods. Patients with CAD and indications for the ICD implantation were examined. Patients were divided into two groups. In first group before ICD implantation, patients underwent cardiac 99mTc­methoxy­isobutyl­isonitrile scintigraphy for right ventricle wall perfusion disorders assessment. In this group defibrillating lead was implanted to the septal position, if the perfusion disorders were in the apical segments, and to the apical position, if perfusion disorders were in the septal segment. In second group lead was implanted using conventional approach. Fluoroscopy duration and radiation dose were compared.Results. There were 58 patients (male­52, female­6, age­64,5±8,5 years) enrolled. The first group consisted of 27 (46,5%) patients. For 13 (48,1%) patient ICD was implanted for primary, and 14 (51,9%) one for secondary sudden cardiac death (SCD) prevention. In 14 (51,9%) cases in this group defibrillating lead was implanted to the apical and in 13 (48,1%) — to the septal position. The 2­nd group consisted of 31 (53,5%) patients. For 13 (41,9%) patient ICD was implanted for primary, and 18 (58,1%) one for secondary SCD prevention. In 15 (48,3%) cases in this group defibrillating lead was implanted to the apical and in 16 (51,7%) — to the septal position. There were significant differences between groups in terms of fluoroscopy duration  — 85,5±28,1 and 131,6±53,5 sec (р=0,0001) and radiation dose — 0,14±0,07 and 0,21±0,08 (p=0,0004) mSv, respectively.Conclusion. Assessment of right ventricular perfusion before ICD implantation reduce fluoroscopy time and total radiation exposure to staff.

Publisher

Silicea - Poligraf, LLC

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3