Mandibular advancement reduces pharyngeal collapsibility by enlarging the airway rather than affecting velopharyngeal compliance

Author:

Garcia Guilherme J. M.12ORCID,Wolf Josiah J.12,Campbell David A.12,Bailey Ryan S.12,Sparapani Rodney A.3,Welzig Charles M.4,Woodson B. Tucker1

Affiliation:

1. Department of Otolaryngology and Communication Sciences Medical College of Wisconsin Milwaukee Wisconsin USA

2. Joint Department of Biomedical Engineering Marquette University & The Medical College of Wisconsin Milwaukee Wisconsin USA

3. Division of Biostatistics Medical College of Wisconsin Milwaukee Wisconsin USA

4. Department of Medicine Tufts University School of Medicine Boston Massachusetts USA

Abstract

AbstractMandibular advancement devices (MADs) are frequently prescribed for obstructive sleep apnea (OSA) patients, but approximately one third of patients experience no therapeutic benefit. Understanding the mechanisms by which MADs prevent pharyngeal collapse may help optimize MAD therapy. This study quantified the relative contributions of changes in airspace cross‐sectional area (CSA) versus changes in velopharyngeal compliance in determining MAD efficacy. Sixteen patients with moderate to severe OSA (mean apnea–hypopnea index of 32 ± 15 events/h) underwent measurements of the velopharyngeal closing pressure (PCLOSE) during drug induced sedated endoscopy (DISE) via stepwise reductions in nasal mask pressure and recording of the intraluminal pressure with a catheter. Airspace CSA was estimated from video endoscopy. Pharyngeal compliance was defined as the slope of the area–pressure relationship of the velopharyngeal airspace. MAD therapy reduced PCLOSE from a median of 0.5 cmH2O pre‐advancement to a median of −2.6 cmH2O post‐advancement (p = 0.0009), increased the minimal CSA at the velopharynx by approximately 20 mm2 (p = 0.0067), but did not have a statistically significant effect on velopharyngeal compliance (p = 0.23). PCLOSE had a strong correlation with CSA but did not correlate with velopharyngeal compliance. Our results suggest that MADs reduce velopharyngeal collapsibility by increasing airway size as opposed to affecting velopharyngeal compliance. This contradicts the speculation of previous literature that the effectiveness of MADs is partially due to a reduction in velopharyngeal compliance resulting from stretching of the soft palate. These findings suggest that quantification of velopharyngeal CSA pre‐ and post‐MAD advancement has potential as a biomarker to predict the success of MAD therapy.

Funder

National Center for Advancing Translational Sciences

Publisher

Wiley

Subject

Physiology (medical),Physiology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3