Lian Huifang,Ma Weisong,Wei Qiuhong,Yuan Xiaoyong
Abstract
Objectives: To compare early subjective and objective vision quality of postoperative patients undergoing phacoemulsification cataract surgery combined with implantation of refractive segmental multifocal intraocular lens (MIOL) SBL-3 and apodized diffractive MIOL SN6AD1.
Methods: As a prospective study, it enrolled 53 patients (53 eyes) to undergo phacoemulsification cataract surgery combined with MIOL implantation. According to differences in MIOL implanted, patients were divided into a SBL-3 group (25 eyes) and a SN6AD1 group (28 eyes). Ophthalmological evaluation included uncorrected (UDVA) and corrected (CDVA) distance visual acuities, uncorrected intermediate (UIVA) and near (UNVA) visual acuities, distance-corrected intermediate (DCIVA) and near (DCNVA)visual acuities and corrected near(CNVA) visual acuity, contrast sensitivity, modulation transfer function (MTF) and high order aberration (4 mm pupil diameter) at three months postoperatively. Moreover, a questionnaire survey was carried out to assess near spectacle independence, patient satisfaction and symptoms of visual disturbance.
Results: At three months after surgery, UIVA and UNVA in the SBL-3 group are statistically significantly superior to those of the SN6AD1 group (P<0.05). There was statistical difference in contrast sensitivity at four spatial frequencies (3, 6, 12, 18cycles/degree) under mesopic conditions and mesopic conditions with glare (P<0.05). The total ocular high order aberration, coma and trefoil were statistically significantly larger in the SBL-3 group than in the SN6AD1 group with 4.0 mm pupil diameters (P<0.05). Statistical differences were found in the MTF at spatial frequencies of 5, 10 and 15 cycles/degree between the groups. There were no significant differences in spectacle independence, patient satisfaction and visual disturbance between the groups (P>0.05).
Conclusions: Both the two multifocal intraocular lens provided an excellent level of quality of vision three months postoperatively. However, the application effect of SBL-3 MIOL is superior to that of SN6AD1 MIOL as far as intermediate vision, near vision and contrast sensitivity are concerned.
doi: https://doi.org/10.12669/pjms.36.7.3364
How to cite this:Lian H, Ma W, Wei Q, Yuan X. A comparative study on early vision quality after implantation of refractive segmental and diffractive multifocal intraocular lens. Pak J Med Sci. 2020;36(7):1607-1612. doi: https://doi.org/10.12669/pjms.36.7.3364