A comparative study on early vision quality after implantation of refractive segmental and diffractive multifocal intraocular lens

Author:

Lian Huifang,Ma Weisong,Wei Qiuhong,Yuan Xiaoyong

Abstract

Objectives: To compare early subjective and objective vision quality of postoperative patients undergoing phacoemulsification cataract surgery combined with implantation of refractive segmental multifocal intraocular lens (MIOL) SBL-3 and apodized diffractive MIOL SN6AD1. Methods: As a prospective study, it enrolled 53 patients (53 eyes) to undergo phacoemulsification cataract surgery combined with MIOL implantation. According to differences in MIOL implanted, patients were divided into a SBL-3 group (25 eyes) and a SN6AD1 group (28 eyes). Ophthalmological evaluation included uncorrected (UDVA) and corrected (CDVA) distance visual acuities, uncorrected intermediate (UIVA) and near (UNVA) visual acuities, distance-corrected intermediate (DCIVA) and near (DCNVA)visual acuities and corrected near(CNVA) visual acuity, contrast sensitivity, modulation transfer function (MTF) and high order aberration (4 mm pupil diameter) at three months postoperatively. Moreover, a questionnaire survey was carried out to assess near spectacle independence, patient satisfaction and symptoms of visual disturbance. Results: At three months after surgery, UIVA and UNVA in the SBL-3 group are statistically significantly superior to those of the SN6AD1 group (P<0.05). There was statistical difference in contrast sensitivity at four spatial frequencies (3, 6, 12, 18cycles/degree) under mesopic conditions and mesopic conditions with glare (P<0.05). The total ocular high order aberration, coma and trefoil were statistically significantly larger in the SBL-3 group than in the SN6AD1 group with 4.0 mm pupil diameters (P<0.05). Statistical differences were found in the MTF at spatial frequencies of 5, 10 and 15 cycles/degree between the groups. There were no significant differences in spectacle independence, patient satisfaction and visual disturbance between the groups (P>0.05). Conclusions: Both the two multifocal intraocular lens provided an excellent level of quality of vision three months postoperatively. However, the application effect of SBL-3 MIOL is superior to that of SN6AD1 MIOL as far as intermediate vision, near vision and contrast sensitivity are concerned. doi: https://doi.org/10.12669/pjms.36.7.3364 How to cite this:Lian H, Ma W, Wei Q, Yuan X. A comparative study on early vision quality after implantation of refractive segmental and diffractive multifocal intraocular lens. Pak J Med Sci. 2020;36(7):1607-1612. doi: https://doi.org/10.12669/pjms.36.7.3364 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Publisher

Pakistan Journal of Medical Sciences

Subject

General Medicine

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3