Comparing the predicted accuracy of PO2\FIO2 ratio with rapid shallow breathing index for successful spontaneous breathing trial in Intensive Care Unit

Author:

Furqan Dr Aamir,Ali Rai Dr Shumaila,Ali Dr Liaqat,Ahmed Dr Rana Altaf

Abstract

Objective: To compare the predicted accuracy of PFR with RSBI for successful spontaneous breathing trial before extubation in intensive care unit. Methods: This cross sectional study was conducted at the ICU of Ch. Pervaiz Ellahi Institute of Cardiology, Multan Medical and Nishtar Medical University Hospital from July, 2017 to January, 2019. PO2/FIO2 and RSBI was measured by a different investigator, before and 20 minutes after the start of SBT. Heart rate, blood pressure and oxygen saturation were continuously measured throughout the trial. Trial outcome was labeled as unsuccessful or successful by the investigator who was blinded to the rapid shallow breathing index and PO2/FiO2 measurements. Patients with SpO2>85%, stable hemodynamics (HR and BP change <20%), stable respiration (RR change <50%), and the absence of (i) signs of labored breathing, (ii) emergence or worsened discomfort, (iii) change in mental status, were labeled as successful in bearing the SBT. Patients were divided into two groups i.e. successful and unsuccessful, gender, Age, GOLD stage, APACHE II score, pCO2, pO2, FiO2 and RSBI score were compared between the two groups after putting all the data in SPSS version 23. Chi square tests and Student’s t-test were used on the continuous data and nominal data, accordingly. The specificity, sensitivity, diagnostic accuracy, negative predictive value and positive predictive value of two threshold values of RSBI and PO2/FiO2 ratio were calculated from the 2X2 contingency tables. Results: RSBI threshold of 130 had 40.4% sensitivity, 51.1% specificity, 55.2% positive predictive value, 36.4% negative predictive value and 44.7% diagnostic accuracy while RSBI threshold of 105 had 94.1% sensitivity, 43.6% specificity, 71.4% positive predictive value, 83.2% negative predictive value and 73.8% diagnostic accuracy. pO2/FiO2>250 had 76.9% sensitivity, 24.5% specificity, 60.4% positive predictive value, 41.5% negative predictive value and 55.9% diagnostic accuracy. Conclusion: Even though neither rapid shallow breathing nor the PFR was enough accurate in prediction of successful extubation but rapid shallow breathing index 105 threshold had higher sensitivity and specificity as compared to RSBI threshold 130PFR. Therefore, RSBI105 is more accurate in predicting the outcome of extubation of ICU patients. doi: https://doi.org/10.12669/pjms.35.6.788 How to cite this:Furqan A, Rai SA, Ali L, Ahmed RA. Comparing the predicted accuracy of PO2\FIO2 ratio with rapid shallow breathing index for successful spontaneous breathing trial in Intensive Care Unit. Pak J Med Sci. 2019;35(6):1605-1610.  doi: https://doi.org/10.12669/pjms.35.6.788 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Publisher

Pakistan Journal of Medical Sciences

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3