Abstract
Based on the basic principle of four-quadrant-based tracking sensor, the centroid detection error and the displacement sensitivity of four-quadrant detector, caused by noise or crosstalk in multiple anode photomultiplier (PMT tube), are analyzed in detail. The tracking error formula of four-quadrant-based tracking senor is given in theory and verified in experiment. The results show that when the photon-electron number per frame is constant, the tracking error of four-quadrant-based tracking senor increases as the crosstalk in multiple-anode PMT increases, and when the crosstalk in multiple-anode PMT is constant, the tracking error of four-quadrant-based tracking senor decreases as the photon-electron numbers increases.
Publisher
Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
Subject
General Physics and Astronomy
Reference8 articles.
1. Rao C H, Zhang X J, Jiang W H, Tang G M 2002 Acta Opt. Sin. 22 67 (in Chinese) [饶长辉, 张学军, 姜文汉, 汤国茂 2002 光学学报 22 67]
2. Tyler G A, Fried D L 1982 J. Opt. Soc. Am. 72 804
3. Golimowski D A, Clampin M, Durrance S T, Barkhouser R H 1992 Appl. Opt. 31 4405
4. Hayano Y, Takami H, Gaessler W, Takato N, Goto M, Kamata Y, Minowa Y, Kobayashi N, Iye M 2003 SPIE 4839 32
5. Rome M, Fleck H G, and Hines D C 1964 Appl. Opt. 3 691
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献