Author:
Yang Ya-Liang ,Ding Zhi-Hua ,Wang Kai ,Wu Ling ,Wu Lan ,
Abstract
A full-field optical coherence tomography system using an achromatic phase shifter based on a rotating half-wave plate to implement phase shifting is developed. The phase shifter can achromatically introduce phase shift of eight times the rotating angle of the half-wave plate, and can rapidly provide various phase shifts for various algorithms. Real phase shift is measured and the result demonstrates that the system gives a phase shift of eight times the rotating angle of the half-wave plate, showing the achromatic phase shifter model is correct. Imaging experiment results of a mirror using Hariharan algorithm show that the system has high phase shift precision. A coin as the sample is imaged to demonstrate the performance of the system.
Publisher
Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
Subject
General Physics and Astronomy
Cited by
10 articles.