Transmission efficiency and beam reception of the SESRI 300 MeV synchrotron injection line

Author:

Zhao Liang-Chao,

Abstract

SESRI 300 MeV synchrotron in Harbin Institute of Technology is now under construction and the whole equipment has been installed and tested. Before commissioning beam, the beam transport through the injection line is simulated by using a full-scall model through the Tracewin code. The field distribution of RFQ cavity is calculated with CST, and the results are substituted into the Tracewin code to generate the accurate results. The envelop mode and multi-particles mode are used in the beam simulation with two typical beams (H<inline-formula><tex-math id="Z-20220529151953">\begin{document}${}_2^+ $\end{document}</tex-math><alternatives><graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="11-20212112_Z-20220529151953.jpg"/><graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="11-20212112_Z-20220529151953.png"/></alternatives></inline-formula> and <sup>209</sup>Bi<sup>32+</sup>, the lightest beam and the heaviest beam). Both beams are accelerated from 4 keV/u to 2 MeV/u by an RFQ cavity and two IH-DTL cavities. Then the H<inline-formula><tex-math id="Z-20220529152018">\begin{document}${}_2^+ $\end{document}</tex-math><alternatives><graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="11-20212112_Z-20220529152018.jpg"/><graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="11-20212112_Z-20220529152018.png"/></alternatives></inline-formula> beam is stripped into a proton beam by a carbon foil and accelerated to 5.6 MeV with the third IH-DTL cavity. Simulation results show that the strength of the magnetic field and the acceleration field are proportional to the mass charge ratio. The beam transmission efficiency and the injection line reception are inversely proportional to the beam transverse emittance. The <sup>209</sup>Bi<sup>32+</sup> beam transmission efficiency and beam reception (momentum spread less than ±0.2%) are 72.16% and 46.72% with transverse emittance <i>ε</i> = 0.12π mm·mrad (ECR source output) and <i>ε</i> = 0.4π mm·mrad (RFQ output). H<inline-formula><tex-math id="Z-20220529152204">\begin{document}${}_2^+ $\end{document}</tex-math><alternatives><graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="11-20212112_Z-20220529152204.jpg"/><graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="11-20212112_Z-20220529152204.png"/></alternatives></inline-formula> beam transmission ratio and beam reception are 24.19% and 17.89% with <i>ε</i> = 0.2π mm·mrad (ECR source output) and <i>ε</i> = 0.5π mm·mrad (RFQ output). In order to obtain high transmission efficiency and beam reception, the transverse emittance should be limited to 0.1π mm·mrad after the RFQ. With this limitation, the <sup>209</sup>Bi<sup>32+</sup> beam transmission efficiency and the reception are increased to 96.68% and 92.63%, respectively, and the H<inline-formula><tex-math id="Z-20220529152129">\begin{document}${}_2^+ $\end{document}</tex-math><alternatives><graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="11-20212112_Z-20220529152129.jpg"/><graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="11-20212112_Z-20220529152129.png"/></alternatives></inline-formula> beam transmission efficiency and the rception rise to 74.40% and 68.18%, respectively. If two additional quadrupole magnets are added, the H<inline-formula><tex-math id="Z-20220529152030">\begin{document}${}_2^+ $\end{document}</tex-math><alternatives><graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="11-20212112_Z-20220529152030.jpg"/><graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="11-20212112_Z-20220529152030.png"/></alternatives></inline-formula> beam transmission efficiency and beam reception can be increased to 90.73% and 83.61%, respectively, which will fulfill the requirement for long-time operation. The phase space change process shows that loss of <sup>209</sup>Bi<sup>32+</sup> beam is caused mainly by longitudinal defocusing (energy spread and phase width spread), the loss of proton beam is caused both by the longitudinal defocusing and by the transverse defocusing (beam envelop spreading), that is why two additional focusing magnets should be added in proton beam acceleration. Results also show that by using field distribution calculation in the simulation process the greater influence of the cavity design details can be confirmed such as beam off-axis caused by dipole field in the IH-DTL cavity and beam loss caused by unperfect field in the RFQ. Tracking with field distribution is shown to be a useful method to link the cavity design process, beam line design process, and beam commission process.

Publisher

Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences

Subject

General Physics and Astronomy

Reference21 articles.

1. Qian C, Sun L T, Jia Z H 2020 Rev. Sci. Instrum 91 023313

2. Liu M 2017 M. S. Dissertation (Lanzhou: Institute of Modern Physics) (in Chinese)
刘明 2017 硕士学位论文 (兰州: 近代物理研究所)

3. Yu J W, Yang Y Q, Lü M B, Cheng W J, Zheng Y J, Xu X W, Lu H J, Pan Y X 2021 High Power Laser and Particle Beams 33 054001
喻九维, 杨雅清, 吕明邦, 陈文军, 郑亚军, 许小伟, 陆海娇, 潘永祥 2021 强激光与粒子束 33 054001

4. Li Z S 2017 Ph. D. Dissertation (Lanzhou: Institute of Modern Physics) (in Chinese)
李钟汕 2017 博士学位论文 (兰州: 近代物理研究所)

5. Ren H T, Pozdeyev E, Lund M S 2016 Rev. Sci. Instrum. 87 02B919

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3