NO2 measurement using fiber coupled broadband LED source combining a Herriott multi-pass cell

Author:

Cao Yuan,Tian Xing,Cheng Gang,Liu Kun,Wang Gui-Shi,Zhu Gong-Dong,Gao Xiao-Ming, ,

Abstract

An NO<sub>2</sub> sensor based on a fiber coupled broadband LED source with a Herriott multi-pass cell is developed and demonstrated for calibrating aerosol absorption photoacoustic (PA) spectrometer. At first, a Herriott multi-pass cell with an effective optical path of 26.1 m is designed based on the theory of light transmission, for increasing the light absorption of NO<sub>2</sub> in the cell. It is difficult to obtain a high-quality beam of LED by using the conventional collimating method that enables the collimated output beam to transmit back and forth in the multi-pass cell, due to the large emitting surface and divergence angle of the LED. So, in the present work, the emission of the LED is coupled into a single model fiber, and then collimated by using a lens. The LED spectrum does not change before and after fiber coupling. The collimated beam with a central wavelength of 438.5 nm is coupled into the multi-pass cell. The output beam passing through the multi-pass cell is detected by using a spectrometer for retrieving the NO<sub>2</sub> concentration. Finally, an expected concentration detection limit of 1 μmol/mol (3<i>σ</i>) is achieved within 1 s acquisition time and the signal-to-noise ratio (SNR) is 40. By analyzing the result measured with 46 μmol/mol NO<sub>2</sub>, a measurement precision of 0.1% is achieved. In order to calibrate the aerosol absorption PA spectrometer, the NO<sub>2</sub> sensor and the aerosol absorption PA spectrometer based on 450 nm are used to measure different concentrations of NO<sub>2</sub>, simultaneously. The results show that the measured NO<sub>2</sub> concentration has a good linear relationship with the PA spectrum signal, and the linearity is better than 99.9%. This good linear relationship further shows the feasibility and reliability of the NO<sub>2</sub> sensor. The slope of calibration curve after normalizing the power is 0.95 nV/(mW·Mm<sup>-1</sup>). Using this calibration result, the PA signal measured with aerosol absorption PA spectrometer is transformed into the absorption coefficient. The developed NO<sub>2</sub> measuring system based on a broadband LED light source and Herriott multi-pass cell has the advantages of low cost, simple structure and easy use. It can be used to calibrate the aerosol absorption PA spectrometer, and also to measure NO<sub>2</sub> in industry.

Publisher

Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences

Subject

General Physics and Astronomy

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3