Instrument line shape function of laser heterodyne spectrometer

Author:

Lu Xing-Ji,Cao Zhen-Song,Tan Tu,Huang Yin-Bo,Gao Xiao-Ming,Rao Rui-Zhong, ,

Abstract

Laser heterodyne is a kind of technique based on coherent detection with high sensitivity and spectral resolution for spectrum measurements. For these reasons, it has been widely used in many research fields, such as trace gases’ detection of earth’s or terrestrial planets’ atmosphere. However, when the laser heterodyne spectrometer is used for measuring the spectrum, the instrument line shape (ILS) function usually smooth the spectrum, which affects the inversion results of the gas column density. In previous researches, the radio frequency (RF) filter response function was usually used as the ILS, but recent studies indicated that the ILS without consideration of the influence of lock-in amplifier was not precise enough. In order to obtain the ILS function of the laser heterodyne spectrometer, the main factors which influence the ILS are analyzed, including the RF filter bandwidth, integral time and low-pass filter of lock-in amplifier, and the process is based on the principle of laser heterodyne technology and the flow of heterodyne signal processing. The presented ILS is the convolution of RF filter, wavelength variation in the integral time and the low-pass filter. In addition, for testing the effectiveness of the ILS in this paper, the laser heterodyne spectrometer which was built in our laboratory is used for the multiple measurement of the absorption of water vapor and methane in the band of 3.53 <inline-formula><tex-math id="M2">\begin{document}${\text{μm}}$\end{document}</tex-math><alternatives><graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="6-20181620_M2.jpg"/><graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="6-20181620_M2.png"/></alternatives></inline-formula> and the column densities are retrieved with different ILS. The experimental results show that the actual resolutions of the laser heterodyne spectrometer are about 0.005 cm<sup>–1</sup> and 0.025 cm<sup>–1</sup> when the integral times are set to be 10 ms and 100 ms respectively. Furthermore, the RF filter response function and the ILS function presented in the paper are respectively used in the procedure of water vapor and methane inversion. The results show that when the ILS function used for the retrieval, the sum of squared residual reduces about 16% and the residuals at the peak of methane absorption reduces almost 100% compared with the scenario when using the RF filter function. Above all, the comprehensive analysis of the laser heterodyne spectrometer in this paper indicates that the ILS function is more precise than pioneering studies and this work will be helpful for retrieving the precise profiles of trace gases.

Publisher

Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences

Subject

General Physics and Astronomy

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3