Development of high-pressure multi-wire proportional chamber neutron detector for the China Spallation Neutron Source multipurpose reflectometer

Author:

Wen Zhi-Wen ,Qi Hui-Rong ,Zhang Yu-Lian ,Wang Hai-Yun ,Liu Ling ,Wang Yan-Feng ,Zhang Jian ,Li Yu-Hong ,Sun Zhi-Jia , , , ,

Abstract

As a multipurpose reflectometer device, the two-dimensional (2D) position resolution neutron detector with a 200 mm×200 mm effective area is developed for China Spallation Neutron Source (CSNS) in Dongguang, China. Due to the requirements for the specific parameters of the multipurpose reflectometer, it should be designed to have a more than 50% (@2 Å) detection efficiency, better than 2 mm position resolution and 3 times n/γ resolution ability during the whole operation period of 10 years. The high pressure multi-wire proportional chamber (MWPC) neutron detector filling 3He gas is used as a key detector. Some simulation results and the experimental results show that the optimized thickness of the neutron entrance window should be 9 mm with using the 7075 aluminum alloy, the high pressure chamber should be sealed by the aluminous ring and a gas mixture should be filled with 6 bar 3He+2.5 bar C3H8. The assembled detector can achieve a more than 54% (@2 Å) detection efficiency in the normal operation.With the 100 μm wide collimator slit, the position resolution for X-rays is about 0.235 mm. Therefore, the position resolution for neutron is about 1.4 mm when 2.5 bar propane is used as the stopping gas for proton and triton. In the chamber, the water vapor, the oxygen and the organic impurity gases will reduce the gas gain, cause the detector electrodes to break down and the detector to speed up aging. To solve the outgassing effect of the detector components and keep the stable operation, the recycled device is designed to have the purification function for the working gases. It could purify the working gas at a flow rate of 2 L/min to remove the oxygen, the water vapor and the organic impurity gases. The detector gain increases about 27% with the purification function. Finally, the n/γ resolution and 2D imaging ability of the detector are tested with the 252Cf neutron source in Institute of High Energy Physics, Chinese Academy of Sciences, the peak ratio of neutron to gamma is obtained to be above 5 from the energy spectra and the detecor has good 2D imaging ability. The performance of the high-pressure MWPC neutron detector could meet the requirements for the multipurpose reflectometer, and the detector will be mounted in the CSNS in this year.

Publisher

Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences

Subject

General Physics and Astronomy

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3