Development of quantum voltage noise source chip for precision measurement of Boltzmann constant

Author:

Wang Lan-Ruo ,Zhong Yuan ,Li Jin-Jin ,Qu Ji-Feng ,Zhong Qing ,Cao Wen-Hui ,Wang Xue-Shen ,Zhou Zhi-Qiang ,Fu Kai ,Shi Yong , , ,

Abstract

The Johnson noise thermometer is used to precisely measure Boltzmann constant by comparing the thermal noise caused by charge movement and the quantized voltage reference noise synthesized by the quantum voltage noise source (QVNS). The QVNS signal is synthesized based on quantized voltage pulses produced by two channels of superconducting Josephson junction arrays, which are designed for cross-correlation electronics. The Nb/NbxSi1-x/Nb Josephson junction is used as a core device of QVNS chip in this work for its non-hysteretic current-voltage (I-V) characteristics and conveniently adjustable barrier parameters.In this paper, we present the design consideration, fabrication process, and measurement results of the QVNS chip. The QVNS chip contains two Josephson junction arrays, each consists of four 6 μm×12 μm junctions and is embedded in a 50 Ω coplanar waveguide transmission line. The random noise in signals from the two driven channels is eliminated by cross-correlation, and then an accurate quantum noise is obtained. Test chips with different areas of Josephson junctions are also designed on the same mask, aiming at estimating the variation range of Ic. The typical fabrication process for voltage standard chips in our laboratory is used for preparing the QVNS chip.The sample is measured at 4.2 K. The DC I-V curve shows that the critical current Ic is 6.1 mA. The I-V characteristics of the junctions under 5 GHz microwave radiation are measured. For a series array of four junctions, a 41.44 μV one-stage Shapiro step is observed. Calculation shows that the error between the measurement and theoretical value of 41.36 μV is about 1.9‰, which means that the QVNS chip performs well under microwave radiation and can be used for synthesizing the AC quantum voltage reference noise.A single-frequency 100 kHz sinusoidal waveform is synthesized by the QVNS chip under pulse driven signal. A spectrum of the synthesized sinusoidal waveform shows a single peak, which means that the digital pulse signal is perfectly filtered by Josephson junction arrays and the synthesized signals possess quantum accuracy. The results indicate that our chip has good dynamic response and works well in synthesizing a single-frequency AC quantum voltage signal. This work can provide core devices for the noise thermometry system and support the precise measurement of Boltzmann constant as well as redefinition of Kelvin in future. As a next step, the design and package will be further improved, and the probe module will be optimized to reduce the measurement uncertainty.

Publisher

Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences

Subject

General Physics and Astronomy

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3