Dual-channel quantitative phase microscopy based on a single cube beamsplitter interferometer

Author:

Sun Teng-Fei ,Lu Peng ,Zhuo Zhuang ,Zhang Wen-Hao ,Lu Jing-Qi , ,

Abstract

Quantitative phase microscopy, as a non-destructive and non-invasive measurement technique, can indirectly reflect three-dimensional (3D) morphology and optical properties of transparent microstructure object by measuring phase information. In recent years, this kind of technique has been widely used to detect and investigate the characteristics of biological cells and it has become more and more important in the field of modern biomedical and life science. In this paper, only by using a single cube beamsplitter interferometer, a simple single-shot dual-channel quantitative phase microscopic measurement technique is demonstrated for 3D quantitative phase imaging of biological cells. In the proposed method, a conventional non-polarized cube beamsplitter is the most pivotal element. Unlike its traditional application method, the cube beamsplitter is tilted in a nonconventional configuration and the illumination beam is only incident on the left (or right) half of the cube beamsplitter (just the one side of central semi-reflecting layer), and a very small angle is introduced between the central semi-reflecting layer and the optical axis of incident beam. Based on the light splitting characteristic of the cube beamsplitter, two replicas of incident beam are generated. These two generated replicas (transmission beam and reflection beam) are of symmetry with respect to each other, and they will encounter and form interference when the direction of the incident beam meets a certain condition. Adjust the sample to a suitable position and make it only contact one half of incident beam, and the modulated beam will be seen as the object beam and the remaining clean half of incident beam as the reference beam. When the interference phenomenon occurs, two interference channels with a relative π (rad) phase-shift in one interferogram are acquired simultaneously only using one digital camera, and the higher spatial frequency of interference fringes can be achieved by adjusting a relatively big angle between the central semi-reflecting layer and the optical axis of incident beam. Because of the off-axis interference mode, we only need to record one interferogram to gain the continuous phase information and avoid using complex phase-shift techniques. At the same time, this proposed method is of simple structure and easy to operate due to using less ordinary off-the-shelf optical elements. All these simplify the structure of the system and reduce the cost of the system as much as possible. Finally, the phase information of paramecium is successfully obtained from different interference channels respectively. Furthermore, according to the characteristic of π (rad) phase-shift, we also realize the calibration and determination of ultimate precise phase information of sample by using the method of averaging between these two channels. The experimental results show that our proposed method is suitable for 3D surface morphology measurement of small transparent samples.

Publisher

Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences

Subject

General Physics and Astronomy

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3