Design and optimization of photoacoustic CO gas sensor for fault diagnosis of SF6 gas insulated equipment

Author:

Yin Xu-Kun,Dong Lei,Wu Hong-Peng,Liu Li-Xian,Shao Xiao-Peng, , ,

Abstract

Trace gas analysis for SF<sub>6</sub> decomposition is a powerful diagnostic method to identify partial discharge problem occurring in electrical equipment. In particular, it is recognized that the SF<sub>6</sub> decomposition gases (such as CO, H<sub>2</sub>S, SO<sub>2</sub> and CF<sub>4</sub>) can effectively determine the inner insulation condition of the electrical equipment. Currently, most of researches of diagnostic methods cannot meet the online high-precision detection of gas derivatives in SF<sub>6</sub> electrical insulation equipment. Therefore, there is a need of developing a sensitive, selective and cost-effective sensor system for CO detection in an SF<sub>6</sub> buffer gas environment due to the fact that the power system is filled with pure SF<sub>6</sub> as the dielectric gas, which means that the concentration of SF<sub>6</sub> is usually > 99.8%. The traditional photoacoustic CO gas sensors cannot be directly used in power system, since several SF<sub>6</sub> physical constants strongly differ from those of N<sub>2</sub> or air. In addition, SF<sub>6</sub> molecule reveals uninterrupted and strong absorption lines in the mid-infrared spectral region. In this work, a CO gas sensor working in high concentration SF<sub>6</sub> background gas is designed by using a distributed feedback (DFB) laser as an excitation source with a center wavelength of 2.3 μm. The absorption line strength of 2.3 μm is ~ two orders of magnitude higher than the absorption line strength around 1.56 μm, which can improve the sensor detection performance. A background-gas-induced high-<i>Q</i> differential photoacoustic cell is simulated numerically and tested experimentally. The quality factor of the designed photoacoustic cell in pure SF<sub>6</sub> gas is 85, which is ~ 4 times higher than that in N<sub>2</sub> carrier gas. The experimental results show that the maximum gas flow rate of the differential structure photoacoustic cell is ~ 6 times higher than that of the single resonant cavity photoacoustic cell. After optimizing the resonance frequency, gas velocity and working pressure of the sensor system, the detection sensitivity of the volume fraction of 1.85 × 10<sup>–6</sup> is achieved. In the case of the volume fraction of 50 × 10<sup>–6</sup> CO/SF<sub>6</sub> gas mixture, the maximum photoacoustic signal amplitude of 19.6 μV is obtained, the corresponding normalized noise equivalent concentration (1σ) is 3.68 × 10<sup>–8</sup> cm<sup>–1</sup>·W·Hz<sup>1/2</sup> in 1 s integration time. A linear fitting is implemented to evaluate the response of the sensor from 50 × 10<sup>–6</sup> to 1000 × 10<sup>–6</sup>, resulting in an <i>R</i> square value of 0.9997. The CO photoacoustic gas sensor has high sensitivity, good selectivity and strong noise immunity, which can provide an on-line detection technology for potential insulation fault diagnosis in the power system. The capability of CO gas sensor can be improved by using a higher excitation optical output power and/or reducing the PAC resonator volume to increase the cell constant.

Publisher

Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences

Subject

General Physics and Astronomy

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3