Analysis of influence of long back focal length on athermal design based on infrared multispectral camera

Author:

Xu Huan-Yao,Xu Liang,Shen Xian-Chun,Xu Han-Yang,Sun Yong-Feng,Liu Wen-Qing,Liu Jian-Guo, ,

Abstract

Under different ambient temperatures, the thermal aberration certainly affects the imaging quality of infrared multi-spectral camera. Therefore, an athermalized model of infrared multi-spectral cameras is established, and in this model the ambient infrared multispectral camera is equivalent to a separated dual-lens optical system. In the case of the fixed focal length, the influence of the back focal length on the change of the focal power of the front lens and back lens is analyzed. Now, the variation range of the front and rear lens interval is assumed to be restricted. When the back focal length is smaller than the focal length, the ratio of the absolute value of the focal power of the front lens to the absolute value of the focal power of the back lens decreases with the back focal length increasing. The material of the front lens and the back lens have a longer interval on the thermogram. When the back focal length is greater than the focal length, the scenario becomes exactly opposite. Combined with the judgment method of the positive value and negative value of the focal power on the thermogram, the selection range of materials is constrained by the positive value, negative value, and absolute value of focal power, thus realizing the rapid selection of the optical materials. This method is used to design an athermalized infrared multispectral camera with a waveband of 8–14 μm, a focal length of 50 mm, and an <i>F</i> number of 1.4 in a range from –40 ℃ to +60 ℃. Through the simulation analysis, the value of the athermalized infrared multispectral camera, at the Nyquist frequency of 30 lp/mm reaches 0.39, which is close to the diffraction limit; the root mean square radius of the diffuse spot is smaller than the Airy spot radius of 19.17 μm; the axial aberration is less than 0.02 mm, and the design results show that this method can make the long back-focus infrared optical system maintain stable imaging quality in a large temperature range. The SF<sub>6</sub> gas is detected experimentally, and the experimental results demonstrate the excellent optical performance of the system.

Publisher

Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences

Subject

General Physics and Astronomy

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3