Response to 14 MeV neutrons for single-crystal diamond detectors
-
Published:2021
Issue:20
Volume:70
Page:202901
-
ISSN:1000-3290
-
Container-title:Acta Physica Sinica
-
language:
-
Short-container-title:Acta Phys. Sin.
Author:
Huang Guang-Wei,Wu Kun,Chen Ye,Li Lin-Xiang,Zhang Si-Yuan,Wang Zun-Gang,Zhu Hong-Ying,Zhou Chun-Zhi,Zhang Yi-Yun,Liu Zhi-Qiang,Yi Xiao-Yan,Li Jin-Min, , ,
Abstract
Single-crystal diamond (SCD) detectors promise to have applications in neutron spectrometers and fusion neutron monitoring under high flux deuterium plasma. The response to 14 MeV neutrons for the SCD detector is studied in this paper. A high-performance SCD neutron detector is developed by processing cleaning wafer, depositing metal electrodes, annealing and wire-bonding. A fast-neutrons monitoring system containing the detector, preamplifier and digital multichannel analyzer is constructed, and the response to 14 MeV neutrons for the detector is measured on the K-400 neutron generator supported by China Academy of Engineering Physics. In addition, computational simulations of the energy deposition and detection efficiency of 14 MeV neutron through diamond are performed via Geant4 toolkit based on evaluated nuclear data libraries of ENDF-VIII.0, JEFF-3.3, BROND-3.1, JENDL-4.0u and CENDL-3.1. The methods of widening the simulation spectrum and calibration of measuring spectrum are presented in order that simulation results are in reasonable agreement with measured values. The results indicate that the energy deposition of 14 MeV neutrons incident on the <sup>12</sup>C can be more accurately calculated with CENDL-3.1 than with other data libraries. The elastic scattering and reaction of <sup>12</sup>C(n, 3α) are described more accurately with the CENDL-3.1, and the characteristic peaks of <sup>12</sup>C(n, α)<sup>9</sup>Be matched well the calibrated testing spectrum and the after-widening simulation spectrum, with a difference between the simulated detection efficiency and measuring results being as low as 0.61%. The outcome measures are described as the standardized mean difference, with a detection efficiency of (3.31 × 10<sup>–4</sup> ± 0.11 × 10<sup>–4</sup>) counts/n, an energy resolution of 4.02% ± 0.09%, and a peaking channel of 1797.24 ± 0.80, which suggest that the detector keeps stable well under a high neutron flux of 2 × 10<sup>10</sup> n/s for as long as 2 h. The results demonstrate that the SCD detector can be a promising candidate for monitoring 14 MeV D-T neutrons.
Publisher
Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
Subject
General Physics and Astronomy
Reference21 articles.
1. Thomas D, Bedogni R, Méndez R, Thompson AZimbal A 2018 Radiat. Prot. Dosim. 180 21 2. Bertalot L, Krasilnikov V, Core L, Saxena A, Yukhnov N, Barnsley R, Walsh M 2019 J. Fusion Energ. 38 283 3. Cazzaniga C, Sunden E A, Binda F, et al. 2014 Rev. Sci. Instrum. 85 43506 4. Luo J H 2021 14MeV Neutron Physics and Cross Section Measurements (Beijing: Science Press) p17 (in Chinese) 罗均华 2021 14 MeV中子物理及截面测量 (北京: 科学出版社) 第17页 5. Osipenko M, Ripani M, Ricco G, Caiffi B, Pompili F, Pillon M, Angelone M, Verona-Rinati G, Cardarelli R, Mila G, Argiro S 2015 Nuclear Instruments & Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment 799 207
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|