A synchroscan streak tube with high deflection sensitivity

Author:

Liu Xue-Ling,Tian Jin-Shou,Tian Li-Ping,Chen Ping,Zhang Min-Rui,Xue Yan-Hua,Li Ya-Hui,Fang Yu-Man,Xu Xiang-Yan,Liu Bai-Yu,Gou Yong-Sheng, , , ,

Abstract

A synchroscan streak tube with high spatiotemporal resolution and high deflection sensitivity is proposed, which contains several innovation designs. Some measures are taken to improve the imaging performances of the streak tube. Firstly, in order to obtain a high deflection sensitivity, the difference in voltage between the photocathode and anode and the length of the equipotential region of the streak tube are reduced as much as possible. Secondly, by introducing a hyperfine grid behind the cathode, reasonably designing the voltages applied to the six-electrode electrostatic focusing system, and moving the electron beam crossing point to the entrance of the deflection plates, the temporal dispersion and the temporal distortion of the streak tube are reduced, and the spatiotemporal resolution of the streak tube is improved. Besides, the streak tube is technically analyzed by tracking the temporal and spatial distribution of electrons under an operating voltage of 7000 V with the aid of computer simulation technology (CST) software. The results show that the deflection sensitivity is 125 mm/kV, the physical temporal resolution is better than 1.83 ps @MTF = 10%, and the static spatial resolution on the photocathode is better than 38 lp/mm @MTF = 10% over the effective photocathode area with a size of 10 mm × 4 mm. By applying a synchronous scanning voltage with a repetition frequency of 250 MHz to the deflection electrode, the results show that the dynamic spatial resolution of the streak tube is better than 16 lp/mm, the limit of the dynamic temporal resolution is 1.39 ps, and two rectangular electron pulses with a size of 10 mm × 20 μm and an interval of 2.3 ps emitted from the photocathode can be well resolved by the streak tube. In addition, the experimental measurements are conducted with a streak tube developed in our laboratory. The results demonstrate that the photocathode of the streak tube can work in the entire visible light region, and the response in the short wavelength region is significantly better than that in the long wavelength region. The static spatial resolution of this streak tube is 40 lp/mm in the center of the photocathode. The temporal resolution of this streak tube is 5.55 ps measured under a synchronous scanning voltage with a repetition frequency of 75 MHz.

Publisher

Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences

Subject

General Physics and Astronomy

Reference30 articles.

1. Wang J G 2012 Ph. D. Dissertation (Hefei: University of Science and Technology of China) (in Chinese)
王季刚 2012 博士学位论文 (合肥: 中国科学技术大学)

2. Guo B P, Cunin B, Niu H B 2005 Acta Photonic Sin. 34 442
郭宝平, Cunin B, 牛憨笨 2005 光子学报 34 442

3. Niu H B, Liu Y P, Yang Q L 1988 Acta Photonic Sin. 17 12
牛憨笨, 刘月平, 杨勤劳 1988 光子学报 17 12

4. Zhang H W 1986 Acta Photonic Sin. 15 43
张焕文 1986 光子学报 15 43

5. Adams M C, Sibbett W, Bradley D J 1980 Adv. Electron. Electron Phy. 52 265

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3