Development of 200 kV multi-function pulsed radiation system

Author:

Lü Ze-Qi,Xie Yan-Zhao,Gou Ming-Yue,Chen Xiao-Yu,Zhou Jin-Shan,Li Mei,Zhou Yi,

Abstract

<sec>A multi-functional pulsed radiation system with a peak voltage of 200 kV, an impedance of 2 Ω, and a full width at half maximum (FWHM) of 30 ns is developed. The system can be switched flexibly in two states of generating pulsed electron beam and pulsed X-ray by changing the cathode and anode. It consists of a pulse power driving source, a vacuum diode, and an experimental cavity. A Marx generator, a high energy storage water transmission line, and two pulse compression switches are utilized to generate a high voltage on diode. An effector can be placed in the experimental cavity which has the same vacuum as diode. An insulation structure of transmission line and a diode are optimized to guide in system design. The system can provide a multi-functional experimental platform for investigating pulse power technology, system-generated electromagnetic pulse, biological radiation effect, etc.</sec><sec> The Marx generator generates a high-voltage pulse with hundreds of nanoseconds in FWHM and hundreds of kilovolts in peak value. The pulse is compressed by the main switch and pulse forming switch and then loaded to the diode. Electrons are emitted from diode cathode under the high-voltage pulse and accelerated in the gap. The electrons are extracted directly or converted into X-ray through the anode. Aluminized polyethylene is used as an anode when pulsed electron beam is generated, and tantalum film is used when pulsed X-ray is generated. Working state can be switched by changing the cathode and anode of diode.</sec><sec> The result shows that a current of 83 kA pulsed electron beam and an average energy of 67 keV X-ray are generated. Pulsed X-ray has good uniformity and low electron proportion (0.02%). In order to monitor the operation state and output parameter of the system comprehensively, a complete measurement system is established. Three capacitive voltage dividers are set at the beginning of transmission line, the end of pulse forming line, and the end of output line, while a B - dot current monitor is set at the diode. A Faraday cup is developed to measure the current intensity and the total energy of pulsed electron beam. For energy spectrum, dose and electron proportion, the measurement system composed of pulsed X-ray including spectrometric system, dose system and Rogowski Coil is build.</sec>

Publisher

Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences

Subject

General Physics and Astronomy

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3