Femtosecond fiber laser for high-stability and high-quality pulse compression

Author:

Lian Fu-Qiang ,Fan Zhong-Wei ,Bai Zhen-Ao ,Liu Yi-Zhou ,Lin Wei-Ran ,Zhang Xiao-Lei ,Zhao Tian-Zhuo , , , ,

Abstract

We demonstrate a femtosecond fiber master oscillator power amplifier system of high-stability and high-quality pulse compression, which is applied to corneal refractive surgery. The nonlinear-polarization-evolution mode-locking in a hybrid-cavity Yb-fiber oscillator consisting of both polarization-maintaining (PM) and non-PM fibers is demonstrated. In this paper, the PM-fibers introduced into the mode-locked fiber oscillator partially replace non-PM fibers. This alternative approach is conducive to reducing the adverse effect of uncontrolled fiber birefringence, which originates from the on-PM fiber suffering environmental temperature fluctuation and mechanical vibration. Once the length of non-PM fiber is comparable to the fiber beat length, the uncontrolled fiber birefringence caused by environment starts to abate the laser robustness, repeatability, and reliability of mode-locking. The stability becomes notoriously worse for long-cavity Yb-fiber oscillators. The PM-fibers adopted in the mode-locked fiber oscillator could improve the mode-locked stability of nonlinear-polarization-evolution self-started with long-cavity Yb-fiber oscillators. We study the dependence of the compressed pulse quality on the parameters of input pulse pre-chirp injected into the Yb-doped fiber amplifier. Due to the nonlinear-chirp and third order dispersion, the mode-locked pulse shape in time-domain will produce distortion during power being amplified in the Yb-doped fiber amplifier. A diffraction grating to adjust the pre-chirp of the input pulse from positive value to negative value launched into the Yb-doped fiber amplifier is placed between mode-locked Yb-fiber oscillator and Yb-doped fiber amplifier. We vary the pre-chirp by changing the distance between the diffraction grating and triangular prism and then adjust the second grating pair to compress the amplified pulses into its shortest pulse duration of full-width at half maximum measured by an autocorrelator. The experimental results show that the best compression quality of mode-locked pulse occurs at the negative pre-chirp with a measured pulse width of 183 fs. Deviation from this optimum pre-chirp degrades the compressed-pulse quality and features an increased temporal pedestal. The fiber laser produces self-started mode-locking at a repetition rate of 19.4 MHz, an average power of 1.2 W, a pulse width of 183 fs. The homemade femtosecond fiber laser is used to perform surgery on ex vivo pig corneas. The surgey shows that the light burst of femtosecond laser in corneal tissues could cut pig corneas, which proves that the femtosecond fiber laser satisfies the surgical operation requirements of animal corneas.

Publisher

Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences

Subject

General Physics and Astronomy

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3