Asymmetric giant magnetoimpedance of Co-rich melt-extraction microwires

Author:

Zhang Shu-Ling ,Chen Wei-Ye ,Zhang Yong , , , ,

Abstract

The giant magnetoimpedance(GMI) effect of Co-rich microwires makes an opportunity to design sensitive GMI weak magnetic meter sensor. Optimization of magnetic meters needs to improve the GMI response, especially the field sensitivity of microwires. In this study, Co-rich amorphous microwires each with an average diameter of 32 μm are prepared by melt-extracted technique and their GMI characteristics are investigated at frequencies ranging from 0.1 to 10 MHz with and without bias direct voltage applied. Experimental results indicate that the GMI effect of these wires has asymmetric features with the increases of frequency and driving current. It is found that the intrinsic asymmetric GMI (AGMI) response results from the helical anisotropy and magnetization hysteresis of the Co-rich microwires. Furthermore, it is found that there is a pronounced improvement in AGMI response when a bias voltage is applied. In theory, the factor which induces an increase in circular magnetic field causes successive changes in magnetization reversal of the quickly quenched Co-rich microwires with multiple domains and helical anisotropy. As a consequence, the circular magnetization process is enhanced, leading to higher circular permeability and stronger GMI response. Meanwhile, a bias voltage inducing the given circular magnetic field reinforces the magnetization process in a certain direction, which intensifies the asymmetric characteristic of GMI response. For example, the asymmetric ratio between two impedance peaks rises from 1.46% to 12.06% at 1MHz and 3 mA after applying a 1 V bias voltage. Simultaneously, the circular field inclines the magnetization off the axial direction which makes the axially induced magnetization reversal more difficult and occur at a higher switching field. This effect broadens the linear impedance zone; however, it reduces the slope of the impedance with the external field and the field sensitivity increasing to some extent. The balance between these two sides proves that AGMI response is related to the magnetization reversal process which is sensitive to the circular magnetic field. Experimental results indicate that the field sensitivity rises from 616 to 5687 V/T with the impedance linear zone broadening from 0.65 to 1.16 when a 1 V bias voltage is applied, while it decreases to 4525 V/T when the bias voltage futher increases to 2 V at 10 MHz and 5 mA. This reveals that the GMI effect of these amorphous Co-rich microwires with high field sensitivity can be optimized by applying proper bias voltage.

Publisher

Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences

Subject

General Physics and Astronomy

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3