Research on the coherence of partially coherent radially polarized beam during propagation

Author:

Chen Shun-Yi ,Ding Pan-Feng ,Pu Ji-Xiong ,

Abstract

Based on the generalized Huygens theory and the unified theory of coherence and polarization, study is made on the module value of complex degree of coherence of partially coherent radially polarized beam (PCRPB) which changes with transmission distance at different reference point. Results show that the module value distribution of the complex degree changing with the transmission distance is different for different reference point while PCRPB propagates in a free space. When the reference point is at the origin, with the increase of the transmission distance, μxx and μxy hold a symmetric distribution, and the distribution range increases. When the reference point is confined on the x-axis, μxx changes from single peak to three peaks, and the two valleys lie symmetrically; and μxy changes from two peaks to four peaks, and the four valleys lie symmetrically. The transmission distance of the evolution is related to the distance between the reference point and the origin: the closer the distance between the reference point and the origin, the shorter the transmission distance is needed to achieve the evolution process. When the reference point lies on the y-axis, μxx holds a symmetric distribution, its distribution range increases, and μxy changes from two peak values to four peaks and four valleys which are in symmetric form. The transmission distance is related to the spacing between the reference point and the origin, the closer the distance between the reference point and the origin: the shorter the transmission is needed to achieve the evolution process. In addition, when the reference point lies at other positions on the observation plane, the module value distribution of μxx and μxy is obtained by combining the distribution rules of reference point at x-axis and y-axis: i.e., when the reference point lies at other positions of the observation plane, the module values μxx and μxy can be composed of three peaks and four peaks with the increase of transmission distance, respectively.

Publisher

Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences

Subject

General Physics and Astronomy

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3