Author:
Wang Fa-Qiang ,Ma Xi-Kui ,Yan Ye ,
Abstract
Due to the absence of the switching frequency in the conventional average model of the voltage-controlled boost converter, this model cannot be used to analyze the influence of the switching frequency on the Hopf bifurcation in the voltage-controlled boost converter. In this paper, the influence of the switching frequency on the Hopf bifurcation in the voltage-controlled boost converter is analyzed by establishing the improved averaged model, which contains the switching frequency. The circuit is designed, and some typical experimental results are given. It is found that it is effective to use the improved average model to analyze the influence of the switching frequency on the Hopf bifurcation in the voltage-controlled boost converter and the Hopf bifurcation is easy to occur when the switching frequency of the voltage-controlled boost converter decreases.
Publisher
Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
Subject
General Physics and Astronomy
Reference25 articles.
1. Yang X, Pei Y Q, Wang Z A 2004 The Technique of the Switching Power Supplies (Beijing: China Machine Press) p72 (in Chinese) [杨 旭、 裴云庆、 王兆安 2004 开关电源技术(北京: 机械工业出版社)第72页]
2. Wang X M, Zhang B, Qiu D Y 2008 Acta Phys. Sin. 57 2728 (in Chinese) [王学梅、 张 波、 丘东元 2008 物理学报 57 2728]
3. Zhao Y B, Zhang D Y, Zhang C J 2007 Chin. Phys. 16 933
4. Zhang B, Qu Y 2002 Trans. Chin. Electrotech. Soc. 17 43 (in Chinese) [张 波、 曲 颖 2002 电工技术学报 17 43]
5. Cheng W B, Guo Y N, Kang S M, Wang Y L, Huo A Q, Tang N 2009 Acta Phys. Sin. 58 4439 (in Chinese) [程为彬、 郭颖娜、 康思民、 汪跃龙、 霍爱清、 汤 楠 2009 物理学报 58 4439]
Cited by
10 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献