Effects of Bragg periods per grating period on performance of Bragg concave diffraction grating

Author:

Du Bing-Zheng ,Zhu Jing-Ping ,Mao Yu-Zheng ,Liu Hong ,Wang Kai ,Hou Xun ,

Abstract

Concave diffraction gratings (CDGs) have the advantages of being compact, time reliability, cost effective, and channel spacing accuracy. These devices can be used in the wavelength division multiplexing (WDM) systems and micro-spectrometer devices. However, comparing with arrayed waveguides gratings (AWGs), the development of traditional CDGs is far from satisfactory. Because the traditional CDGs need deeply etched facets and perfect grating profiles to reduce the insertion losses, which will increase the difficulty in etching process. In order to solve this problem, Bragg reflectors based CDGs (Bragg-CDGs) are proposed. This structure can greatly reduce the insertion loss, and reduce the difficulty in etching process. The performance of the Bragg-CDG is determined by both the reflection condition of the Bragg reflectors and the diffraction condition of the CDG. With the Bragg reflection condition determined, the diffraction condition of Bragg-CDG will have a major influence on the performance of device. For successive strips based Bragg-CDG, the number of Bragg periods per diffraction grating period is an important parameter of Bragg-CDG. The diffraction condition of concave gratings is closely related to this parameter. This parameter has an effect on the performance of Bragg-CDG, specially termed resolution, the free spectrum range, and the diffraction efficiency. The effect of the number of Bragg periods per diffraction grating period on the Bragg diffraction grating is studied by theoretical analysis. In addition, four Bragg-CDGs with different numbers of Bragg periods are studied using the finite-difference time domain method. The results show that with sizes of diffraction gratings fixed, the resolution of Bragg-CDG does not have a significant improvement by changing the number of Bragg periods per diffraction grating period; the total number of diffraction orders is proportional to the number of Bragg periods per diffraction grating period. The Bragg-CDG with a single Bragg period per grating period has a maximum diffraction efficiency, since it has the minimal number of diffraction orders; in addition, with the increase of the number of Bragg periods per diffraction grating period, the free spectrum range of the main diffraction order gradually decreases. This research can contribute to the development of the demultiplexer with the low insertion loss, the high resolution, and the wide operating waveband.

Publisher

Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences

Subject

General Physics and Astronomy

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3