Author:
Yan Xiao-Song ,Liu Rong ,Lu Xin-Xin ,Jiang Li ,Wang Mei ,Lin Ju-Fang ,
Abstract
In order to check the conceptual design of subcritical reactor, an alternate depleted uranium/polyethylene-shell simulation device was established, to carry out uranium-238 neutron capture rate experiment using activation technique. The depleted uranium foils were activated at 90o to the incident. By measuring the 277.6 keV -ray emitted from 239Np generated by 238U (n, ) 239U reaction and correcting self-absorption of uranium experimentally, the 238U (n, ) reaction rate with an uncertainty between 3.5% and 3.7% and a total neutron capture of 2.24 0.09 of the system were obtained. The experiment was simulated using MCNP5 code with ENDF libraries. The simulations and measurements accord within 5% for the 238U (n, ) reaction rate and within 1% for the total neutron capture rate of 238U.
Publisher
Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
Subject
General Physics and Astronomy
Reference15 articles.
1. Shi X M, Peng X J 2010 Nucl. Power Eng. 31 5 (in Chinese) [师学明, 彭先觉 2010 核动力工程 31 5]
2. Weale J W, Goodfellow H, McTaggart M H, Mullender M L 1961 J. Nucl. Energy 14 91
3. Haight R C, Lee J D, Maniscalco J A 1976 Nucl. Sci. Eng. 61 53
4. Akiyama M, Oka Y, Kanasugi K, Hashikura H, Kondo S 1987 Ann. Nucl. Energy 14 543
5. Wang D L, Chen S H, Kang W, You Y, Huang W D, Zhang X Y 1997 Atom. Energy Sci. Technol. 31 229 (in Chinese) [王大伦, 陈素和, 亢武, 游泳, 黄卫东, 张秀岩 1997 核能科学与工程 31 229]
Cited by
15 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献