Study of the two dimensional imaging performance for the gas electron multiplier using the resistive anode readout method
-
Published:2017
Issue:7
Volume:66
Page:072902
-
ISSN:1000-3290
-
Container-title:Acta Physica Sinica
-
language:
-
Short-container-title:Acta Phys. Sin.
Author:
Ju Xu-Dong ,Dong Ming-Yi ,Zhou Chuan-Xing ,Dong Jing ,Zhao Yu-Bin ,Zhang Hong-Yu ,Qi Hui-Rong ,Ouyang Qun , , ,
Abstract
The new type of micro-pattern gaseous detector (MPGD) like the gas electron multiplier (GEM), features the advantage of good spatial resolution ( 100 m). However, abundant and high density electronic channels are needed to obtain the high spatial resolution, which will lead to a great pressure on the detector construction, power consumption, spatial utilization, etc. The resistive anode readout method can help to obtain a good spatial resolution comparable to the pixel readout structure with an enormous reduction of the electronic channels. By using the thick film resistor technology, a new type of resistive structure, composed of high resistive square pad array with low resistive narrow border strips, is developed and applied to the readout anode of the triple GEM detector. For the resistive anode readout board used in the experiment, there are 66 resistive cells, which means that the detector needs only 49 electronics channels. To obtain a good spatial resolution, the cell size is set to be 6 mm6 mm. The surface resistivity of the pads and the strips are 150 k/□ and 1 k/□, respectively. The performances of the detector, especially the two-dimensional imaging performance, are studied by using a 55Fe (5.9 keV) source and an X ray tube (8 keV). The test results show that the spatial resolution of the detector is better than 80 m () by using the imaging of a 40 m wide slot, and the nonlinearity is better than 1.5% by the scanning along the x-axis of the readout board in the steps of 1 mm. Furthermore, quite a good two-dimensional imaging capability is achieved by the detector. These good performances of the detector show the feasibility of the resistive anode readout method for the GEM detector with large area and other detectors with similar structures in the two-dimensional imaging applications.
Publisher
Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
Subject
General Physics and Astronomy
Reference24 articles.
1. Sauli F 1997 Nucl. Instrum.Meth. A 386 531 2. Dong J, L X Y, Liu B, Liu R G, Ma X Y, Wang L, Chen Y B, Ouyang Q, Xie Y G 2010 Acta Phys. Sin. 59 6029 (in Chinese)[董静, 吕新宇, 刘贲, 刘荣光, 马骁妍, 王岚, 陈元柏, 欧阳群, 谢一冈2010物理学报59 6029] 3. Fan S N, Wang B, Qi H R, Liu M, Zhang Y L, Zhang J, Liu R G, Yi F T, Ouyang Q, Chen Y B 2013 Acta Phys. Sin. 62 122901 (in Chinese)[范胜男, 王波, 祁辉荣, 刘梅, 张余炼, 张建, 刘荣光, 伊福廷, 欧阳群, 陈元柏2013物理学报62 122901] 4. Fan R R, Hou F J, Ouyang Q, Fan S N, Chen Y B, Yi F T 2012 Acta Phys. Sin. 61 092901 (in Chinese)[樊瑞睿, 侯凤杰, 欧阳群, 范胜男, 陈元柏, 伊福廷2012物理学报61 092901] 5. Yang H R, Hu B T, Duan L M, Xu H S, Li C Y, Li Z Y, Zhang X D 2008 Acta Phys. Sin. 57 2141 (in Chinese)[杨贺润, 胡碧涛, 段利敏, 徐瑚珊, 李春艳, 李祖玉, 张小东2008物理学报57 2141]
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|