Measurements of line strengths for some lines of ammonia in 6611-6618 cm-1
-
Published:2017
Issue:5
Volume:66
Page:054207
-
ISSN:1000-3290
-
Container-title:Acta Physica Sinica
-
language:
-
Short-container-title:Acta Phys. Sin.
Author:
Nie Wei ,Kan Rui-Feng ,Xu Zhen-Yu ,Yang Chen-Guang ,Chen Bing ,Xia Hui-Hui ,Wei Min ,Chen Xiang ,Yao Lu ,Li Hang ,Fan Xue-Li ,Hu Jia-Yi , ,
Abstract
The target gas molecular absorption spectrum parameters especially line strengths are very important for measuring temperature and concentration with tunable diode laser absorption spectroscopy (TDLAS) technique. Usually, researchers use line strengths which come from spectrum database, like HITRAN and GEISA and HITEMP spectra database, but those database include values from the theoretical computation, as is well known, there is a big error between the theoretical value and the actual value. In order to modify the line strengths of the database, 20 ammonia spectrum absorption lines in a wavenumber range between 6611 and 6618 cm-1 are measured at different pressures by using direct tunable diode laser absorption spectroscopy (dTDLAS) technique. The measurement procedure is repeated at least 10 times at each pressure, and then average value is calculated. Voigt fitting is used to obtain all line integral area, and then the line integral area is obtained by linear fitting. The slope of the fitting straight line equals line strength. Uncertainty analysis is given for the measurements. The measured linestrength is a function of integrated area, temperature, pressure, species mole fraction and effective path length. So, the calculated linestrength uncertainties based on those parameters uncertainties, and the uncertainties of pressure, species mole fraction and effective path length are similar for all transitions with P =0.25%, =0.2%, and L =0.4%. The uncertainties of the integrated area and temperature are related to different lines, and their values come from the actual measurement. In the end, uncertainty propagation formula is used to calculate linestrength uncetainty. Uncertainties of our measured line strengths are in a 0.81%-3.33% range. Our measured line strength values are different from line strengths in the HITRAN 2012 database, and the deviations are in 0.51%-17.28% range.
Publisher
Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
Subject
General Physics and Astronomy
Reference30 articles.
1. Wang F, Huang Q X, Li N, Yan J H, Chi Y, Cen K F 2007Acta Phys.Sin. 56 3867(in Chinese)[王飞, 黄群星, 李宁, 严建华, 池涌, 岑可法2007物理学报56 3867] 2. Yury A B, Anatoliy A K, Gerard W, Frank K T, Terence H R, John D B 2008LACSEA LMB4 3. Rafal L, Anatoliy A K, David M T, Terence H R, Steven S, Timothy B S, Frank K T 2011SPIE 7945K1 4. Rothman L S, Gordon I E, Babikov Y, et al. 2013J.Quant.Spectrosc.Radiat.Transfer 130 4 5. Jacquinet-Husso N, Scott N A, Chdin A, et al. 2008J.Quant.Spectrosc.Radiat.Transfer 109 1043
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|