Analysis and calibration of precision for point source transmittance system

Author:

Li Zhao-Hui ,Zhao Jian-Ke ,Xu Liang ,Liu Feng ,Guo Yi ,Liu Kai ,Zhao Qing , ,

Abstract

Owing to space optical system working for a long time outside the field of view, where there is strong background radiation, and the fact that the point source transmittance (PST) is an important evaluation indicator for stray light suppression of this optical system, the development of stray light equipment for testing PST has received more and more attention. Though the development of PST testing system has been extensively studied, none of them elaborate on the calibration of the PST testing system. Besides, most of the PST testing systems are at a laboratory research stage, and the calibration of neither testing stability nor accuracy is recognized. Therefore, on the basis of the PST testing system established, one calibration lens is designed to calibrate the PST testing system. By comparing the measured PST values of the calibration lens with the analyzed values, the PST testing system can be evaluated. The calibration lens model is built to analyze PST values at different off-axis angles by using the ray tracing software Tracepro. We consider the accuracy of modeling, and on the basis of simplifying the structure design, we measure bidirectional reflectance distribution function (BRDF) values of the painted surface of the calibration lens, and then estimate values of lens surface from Harvey-Shack model and PSD theory by taking these property data into the model of simulation. Ultimately PST analyzed values of calibration lens can be obtained. Finally, by comparing the measured values of calibration lens, which are tested by using PST testing system, with the analyzed values, the calibration of the PST testing system is completed. In the PST testing process of calibration lens, by analyzing the data at different off-axis angles, the accuracy of repeated measurements and threshold of PST testing system can be obtained. At the same time, testing errors caused by the stability of light source, detector linearity, air scattering and structure of double cylindrical chamber are analyzed through the testing data. The data show that when double cylindrical chamber clean class is ISO7, the PST threshold of this equipment is 10-8, and the accuracy of repeated measurements is 7.9%. Taking into account the detection capability, the PST threshold of this equipment is 10-10 when environmental condition is better than ISO6.

Publisher

Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences

Subject

General Physics and Astronomy

Reference14 articles.

1. Kemp J C, Wyatt C L 1977 Opt. Eng. 16 164412

2. Fleming J, Grochocki F, Finch T, Willis S, Kaptchen P 2008 Proc. SPIE 7069 70690O

3. Peterson G L 2008 Proc. SPIE 7069 70690M

4. Liao S, Shen M Z 1996 J. Infra. Milli. Wave. 15 375 (in Chinese) [廖胜, 沈忙作 1996 红外与毫米波学报 15 375]

5. Wang Z L, Gong Z Q, Zhang W, Wang F G 2011 Opti. Tech. 37 401 (in Chinese) [王治乐, 龚仲强, 张伟, 王付刚 2011 光学技术 37 401]

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3