Effect of half wave plate angle mismatch on channel modulating imaging result and its compensation

Author:

Li Hao ,Zhu Jing-Ping ,Zhang Ning ,Zhang Yun-Yao ,Qiang Fan ,Zong Kang ,

Abstract

Polarization imaging technology is a powerful tool in remote sensing, bioscience, or other scientific areas science, and it can extract the polarization information of target effectively. As a novel polarization imaging technology, the channel modulating polarization imaging has been widely investigated in recent years, owing to its prominent advantages of compact, snapshot and full-Stokes acquirable. In the polarization imaging system based on Savart Plate, a half wave plate with its optical axis at an angle of 22.5 is used to rotate the vibration direction of each incident light to 45. Thus, the amplitude of the light could be equally divided by the second Savart Plate polariscope. Finally, the different components of light will interfere with each other on the focal plane and the target polarization information will be modulated in the interference pattern. Since the intensity distribution of interference pattern is sensitive to the orientation of the half wave plate, a small mismatch angle of half wave plate will lead to a wrong polarization image. In order to solve this problem, we investigate the relationship between the mismatch angle and the image intensity grabbed by focal plane array (FPA) and propose an error eliminating method to improve the accuracy of polarization imaging. We analyze how the mismatch angle affects the light intensity and deduce the expression of the image obtained by the FPA. According to the expression, the raw image we grabbed directly by the FPA is a superposition of the modulated Stokes images with different carrier frequencies. Compared with the ideal expression, the expression we obtained shows that the channels of Stokes parameter S1 and S2,3 each contain a constant factor which is related to the mismatch angle . On the basis of this expression, we propose a method to measure the mismatch angle by imaging a target twice, one is behind a polarizer that is oriented at 0 and the other at 45. Then we can calibrate the system by calculating the mismatch angle through the demodulated images. To image a target with the calibrated system, we just demodulate the raw image obtained by the FPA and then divide the reconstructed stokes images by the constant factor which is determined by . For a mismatch angle of 0.5, a computer simulation is conducted. The result shows that through the compensation method, the accuracies of S1, S2 and S3 can be increased by 0.06%, 3.49% and 3.49%, respectively.

Publisher

Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences

Subject

General Physics and Astronomy

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3