Measurement of methane gas with high absorbance based on modified wavelength modulation spectroscopy

Author:

Li Shao-Min,Sun Li-Qun,

Abstract

In this paper, the wavelength modulation spectroscopy (WMS) technique is modified and used for measuring methane with large absorbance. The WMS has been frequently used for gas measurement and relies on the linear relationship between the second harmonic amplitude and the gas volume concentration. However, the conventional WMS technique is only applicable for the gas whose absorbance is much smaller than 1, which is because the first-order approximation of Lambert-Beer's law is required in the derivation of the traditional WMS theory, and the first-order approximation holds only at low absorbance, hence the linear relationship between the second harmonic and the gas concentration does not hold at large absorbance. In the modified WMS in this work, it is not necessary to make any approximation to Lambert-Beer's law. The measured light is absorbed by the gas to be measured and then collected by the photodetector. The reference light is directly detected by another photodetector without being absorbed. The output signals of the two photodetectors are transmitted to the computer after implementing analog-to-digital conversion. In this way, the demodulated second harmonic signal remains linear with the gas concentration even at large absorbance. In this work, the traditional WMS theory and the modified WMS theory are both introduced, and a series of methane gas with concentration gradients are measured separately. The experimental results of the traditional WMS and the modified WMS are compared with each other. It is confirmed that the linearity in the traditional WMS theory no longer holds under large absorbance, but the improved WMS can still guarantee the linear relationship between the second harmonic and the methane concentration, which verifies the advantages of the modified scheme. Finally, through Allan's standard deviation analysis, the stability of this methane measurement system reaches the optimal value at the average time of 103.6 s, and the corresponding Allan's standard deviation is 1/26.62×10<sup>–9</sup> volume.

Publisher

Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences

Subject

General Physics and Astronomy

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3