Measurement of Rb isotope ratio by atomic absorption spectroscopy with multi-microchannel array structure cavity
-
Published:2023
Issue:5
Volume:72
Page:053201
-
ISSN:1000-3290
-
Container-title:Acta Physica Sinica
-
language:
-
Short-container-title:Acta Phys. Sin.
Author:
Qi Gang,Huang Yin-Bo,Ling Fei-Tong,Yang Jia-Qi,Huang Jun,Yang Tao,Zhang Lei-Lei,Lu Xing-Ji,Yuan Zi-Hao,Cao Zhen-Song, , , , ,
Abstract
Rubidium (Rb) isotope analysis has important applications in geological exploration and environmental detection. Based on tunable laser atom absorption spectroscopy technology combined with thermal decomposition of the sample, a Rb isotope absorption spectroscopy measurement device is built to detect the Rb isotope ratio stability. And the atomic generator is designed by a new micro-channel array structure, which enhances atomic beam collimation capability, effectively suppresses the doppler effect of the spectrum, and improves the resolution of Rb isotope absorption spectrum. The device adopts tantalum metal to make the atomic generator with a diameter of 6 mm, and the micro-channel array with a diameter of 1 mm is stacked inside the atomic generator which can be heated resistively to 3000 ℃. In this experiment, the Rb carbonate sample is catalyzed to release Rb atom beam at a high temperature of 600 ℃, while a probe laser is used to obtain high resolution Rb absorption spectrum. The Rb isotope ratio (<sup>85</sup>Rb∶<sup>87</sup>Rb) of natural abundance Rb carbonate samples is 2.441±0.02 by combining the inversion of the spectral line parameters, the detection error is 5.9%, and the detection limit of <sup>87</sup>Rb is 1.76‰ (3<i>σ</i>). The experimental results show that the multi-microchannel structure reduces the linewidth of Rb atoms by 450 MHz (half height full width) compared with the counterparts of the single-channel structure, which can effectively distinguish the absorption characteristics of Rb isotopes. The device has a high detection accuracy and a high spectral resolution, which provides a possibility for the metal isotope abundance analysis, and has a broad application prospect.
Publisher
Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
Subject
General Physics and Astronomy
Reference20 articles.
1. Li J, Tang S H, Ma J X, Zhu X K 2021 Rock and Mineral Analysis 40 627 李津, 唐索寒, 马健雄, 朱祥坤 2021 岩矿测试 40 627 2. Zhang Z Y, Ma J L, Zhang L, Zeng P, Liu Y, Wei G J 2020 Earth Science Frontiers 27 123 张卓盈, 马金龙, 张乐, 曾提, 刘颖, 韦刚健 2020 地学前缘 27 123 3. Deng A M, Chen X, Zhang C H, Dong L 2004 J. Time Frequency 27 138 邓爱民, 陈循, 张春华, 董理 2004 时间频率学报 27 138 4. King L A, Gornushkin I B, Pappas D, Smith B W, Winefordner J D 1999 Spectrochim. Acta Part B 54 1771 5. Waight T, Baker J, Willigers B 2002 Chemical Geology 186 99
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|