Comparison and validation of band residual difference algorithm and principal component analysis algorithm for retrievals of atmospheric SO2 columns from satellite observations

Author:

Yan Huan-Huan ,Li Xiao-Jing ,Zhang Xing-Ying ,Wang Wei-He ,Chen Liang-Fu ,Zhang Mei-Gen ,Xu Jin , , , ,

Abstract

Remote sensing technology provides an unprecedented tool for the continuous and real-time monitoring of atmospheric SO2 from volcanic eruption and anthropogenic emission. The Global Ozone Monitoring Experiment (GOME), SCanning Imaging Absorption spectroMeter for Atmospheric CHartographY (SCIAMACHY), and Ozone Monitoring Instrument (OMI) have high SO2 monitoring capability. The OMI, which was launched on the EOS/Aura platform in July 2004, has the same hyperspectral measurements as the GOME and SCIAMACHY, but offers the improved spatial resolution at nadir (1324 km2) and daily global coverage for short-lifetime SO2. For OMI operational SO2 planetary boundary layer (PBL) retrieval, the previous band residual difference (BRD) algorithm has been replaced by principal component analysis (PCA) algorithm, which effectively reduces the systematic biases in SO2 column retrievals. However, there are few studies on the evaluations and validations of PCA SO2 retrievals over China, and the long-term comparisons with BRD SO2 retrievals also need to be conducted. In this study, the accuracies of PCA and BRD SO2 retrievals are validated by using ground-based multi axis differential optical absorption spectroscopy (MAX-DOAS) located in Beijing, and regional atmospheric modeling system, community multi-scale air quality (RAMS-CMAQ) modeling system model which can simulate the vertical distribution of atmospheric SO2. Moreover, BRD and PCA SO2 retrievals from oceanic area, eastern China and Reunion volcanic eruption are compared to find the long-term trend and spatiotemporal differences between SO2 columns. Finally, the uncertainty of SO2 retrieval, caused by measurement errors, band selection and input parameter errors in radiative transfer model, are analysed to understand the limitations of BRD and PCA algorithms. Results show that both PCA and BRD SO2 retrievals over Beijing are lower than ground-based MAX-DOAS measurements of SO2. PCA and BRD SO2 retrievals over eastern China are lower than the simulated SO2 columns from RAMS-CMAQ in winter 2008, but in July and August BRD SO2 columns are higher than RAMS-CMAQ simulations. The values of SO2 columns from BRD over China are more consistent with those from ground-based MAX-DOAS and RAMS-CMAQ model than from PCA. Although PCA algorithm effectively reduces the noise in SO2 column retrieval, SO2 columns from PCA over China are lower than those from BRD. For oceanic area where SO2 amount is nearly zero, the standard deviation of PCA results is lower than that of BRD, but the absolute value of averaged PCA SO2 column is larger than that of BRD. In the case of Reunion volcanic eruption with SO2 columns larger than 25 DU, the BRD SO2 columns are lower than PCA retrievals. Meanwhile, with the increase of SO2 column, the difference between BRD and PCA SO2 retrievals increases. Detailed uncertainty analysis shows the influences of measurement errors, band selection and inputs of radiative transfer model on the retrieval results. This study is important for developing the retrieval algorithm, and can also improve the application of OMI SO2 products.

Publisher

Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences

Subject

General Physics and Astronomy

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3