Photoacoustic temperature measurement based on dual-wavelength method

Author:

Liao Yu ,Jian Xiao-Hua ,Cui Yao-Yao ,Zhang Qi , ,

Abstract

Photoacoustic temperature measurement is a novel technique in which photoacoustic effect is used to measure temperature. It has the advantages of non-invasiveness, high sensitivity and deep penetration depth, which is suitable for monitoring the temperature distribution for the safe deposition of heat energy and efficient destruction of tumor cells during thermotherapy or cryotherapy. However, the present reported methods usually use one single wavelength for photoacoustic temperature measuring and are vulnerable to systematic and environmental influence, including the instability of system caused by fluctuation of laser energy, position displacement of transducer, and tissue complexity, which could reduce the measuring accuracy and stability. To solve this problem, a new photoacoustic temperature measuring method by employing two laser wavelengths is proposed in this paper. Firstly a brief theoretical analysis of dual-wavelengths photoacoustic temperature method is performed based on the linear relationship between photoacoustic signal and tissue temperature under two different wavelengths. Then two different samples including phantom of graphite and ex vivo pig blood are experimented respectively. The experimental temperature is set to be in a range of 26 ℃-48 ℃, which is controlled by a precise hot plate. And for improving the detection accuracy, the dual-wavelengths are selected as 760 and 900 nm for graphite phantom, 820 nm and 860 nm for ex vivo pig blood according to their absorption spectrum repetitively. The obtained results reveal that the temperature measuring correlation coefficients by dual-wavelength method can reach to 0.98 in graphite phantom and 0.99 in ex vivo tissue, respectively. And the average measurement deviation decreases to 0.88 ℃ in dual-wavelength method from 1.31 ℃ for the traditional single wavelength method for graphite phantom. While in ex vivo tissue, the measurement deviation decreases to 0.90 ℃ in dual-wavelength method from the average value 1.45 ℃ for the single wavelength method. Furthermore, the standard deviations of error are respectively reduced by an average of 38% in graphite phantom and an average of 30% in ex vivo tissue, respectively. These results indicate that the dual-wavelength method of photoacoustic temperature measurement can improve both the measuring accuracy and stability, and has a potential to be applied to medical therapy and other biomedical fields.

Publisher

Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences

Subject

General Physics and Astronomy

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3