Confocal-cavity-enhanced Raman scattering of ambient air

Author:

Li Bin ,Luo Shi-Wen ,Yu An-Lan ,Xiong Dong-Sheng ,Wang Xin-Bing ,Zuo Du-Luo , ,

Abstract

Raman spectroscopy is a powerful diagnostic method for gas analysis due to its advantages like non-invasiveness and fast speed. However, its applications are greatly restricted because of the weak signal level caused by small scattering cross section. In order to enhance the Raman signal level and improve the detection sensitivity, a sample cell of confocal cavity is designed and the enhanced Raman signal of ambient air based on this cavity is demonstrated experimentally. The confocal cavity is constructed with a pair of plano-concave reflectors with a curvature radius of 150 mm and reflectivity of 92%. This low reflectivity design not only allows for bandwidth matching with the line-width of excitation laser but also makes the resonant condition satisfied easily. The measured output power of the confocal cavity is over 42 mW in resonant condition, which gives a coupling efficiency of 87.5% when divided with the input power 48 mW. The high coupling efficiency enables the output power efficiently to reach 11 times that for the intra-cavity laser power in one direction. Raman scattering of ambient air is tested to verify the performance of the confocal cavity. In our experiments, the Raman signals are collected in a forward scattering configuration by an imaging Raman spectrometer which is connected to a CCD camera. Strong Raman signals of O2 and N2, even H2O are observed with 1 s exposure time in resonant condition, and rotational lines (O-branch and S-branch) of O2 and N2 are also clearly detected when exposure time is set to be 10 s. Compared with the results obtained without confocal cavity, the Raman signal level is enhanced 17 times and the signal-to-noise ratio is improved twice. In addition, a limit of detection (3) at a magnitude of 200 ppm for CO2 in ambient air is achieved for the resonant confocal cavity. These results indicate that the system can significantly enhance the spontaneous Raman scattering signal level and improve the detection sensitivity. Furthermore, the confocal cavity is applicable to the Raman analyses of other gas samples.

Publisher

Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences

Subject

General Physics and Astronomy

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3