Quantum efficiency calibration for low energy detector in hard X-ray modulation telescope satellite

Author:

Zhu-Yue ,Zhang Zi-Liang ,Yang Yan-Ji ,Xue Rong-Feng ,Cui Wei-Wei ,Lu Bo ,Wang Juan ,Chen Tian-Xiang ,Wang Yu-Sa ,Li Wei ,Han Da-Wei ,Huo Jia ,Hu Wei ,Li Mao-Shun ,Zhang Yi ,Zhu Yu-Xuan ,Liu Miao ,Zhao Xiao-Fan ,Chen Yong , ,

Abstract

Low energy X-ray telescope, working over 0.7-15 keV energy band, is one of the main payloads in the hard X-ray modulation telescope satellite. The primary scientific objectives are to survey large sky area to investigate galactic X-ray transient sources as well as the cosmic X-ray background, and to observe X-ray binaries or black holes for studying the dynamics and emission mechanism in strong gravitational or magnetic field. The detector of low energy X-ray telescope is CCD236, a new generation of swept charge device, which has good time and energy resolution. Quantum efficiency (QE) of the detector has a crucial influence on X-ray spectrum fitting and absolute luminosity calculation. To provide valuable scientific data, QE should be calibrated in detail. In this paper, QE calibration is accomplished with respect to a silicon drift detector (SDD), using an Fe-55 radioactive source, at energy points Mn-Kα (5.899 keV) and Mn-Kβ (6.497 keV). The energies of Mn-Kα and Mn-Kβ are near that of iron-K, which is an important line in X-ray observation. Additionally, Mn-Kα and Mn-Kβ X-ray will partially pass through the depletion region of CCD236, and these energy points can be used to measure the depletion thickness. This experiment is set up in a vacuum cooling chamber. The X-ray source perpendicularly illuminates SDD and CCD236 through a small hole, whose area is far less than those of two detectors; therefore, QE measurements are irrelevant to neither the distance nor the azimuth angle between the X-ray source and the detector. For CCD236, split events should be corrected. Energy spectra of SDD and CCD236 are fitted with two Gaussian distributions, respectively, to obtain peak positions and standard variations of Mn-Kα and Mn-Kβ. With known structure of SDD, the QE of CCD236 can be calculated. QE values at Mn-Kα and Mn-Kβ are 71% and 62%, respectively. QE and temperature are uncorrelated with each other in a temperature range from -95 ℃ to -30 ℃. According to the specific structure of CCD236 and the measured QE, without considering the effect of channel stop, the best-fit thickness of depletion region is obtained to be 38 μm. When CCD236 is applied with different driving or substrate voltages, no obvious variation of QE is observed. It indicates that the thickness values of depletion region with high and low level voltages are equal. Furthermore, it shows that working CCD236 is deep depleted, and the thickness of depletion region will not change because it reaches its maximum, the edge of epitaxial layer and substrate layer.

Publisher

Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences

Subject

General Physics and Astronomy

Reference24 articles.

1. Li T P, Wu M 2008 Physics 37 648 (in Chinese) [李惕碚, 吴枚 2008 物理 37 648]

2. Lu F J, Xu Y P, Zhang F, Liu H W 2016 Mod. Phys. 4 4 (in Chinese) [卢方军, 徐玉朋, 张帆, 刘红薇 2016 现代物理知识 4 4]

3. Chen Y, Cui W W 2016 Mod. Phys. 4 25 (in Chinese) [陈勇, 崔苇苇 2016 现代物理知识 4 25]

4. Holland A, Pool P 2008 Proceedings of SPIE: High Energy, Optical, and Infrared Detectors for Astronomy Ⅲ Marseille, June 23-27, 2008 p7021

5. Wang Y S, Chen Y, Xu Y P, Wang J, Cui W W, Li W, Han D W, Zhang Z L, Chen T X, Li C K 2010 Chin. Phys. C 34 1812

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3