Wettability Alteration of Heavy-Oil/Bitumen Containing Carbonates Using Solvents, high pH Solutions and Nano/Ionic Liquids

Author:

Cao Nahai1,Mohammed M. Almojtaba1,Babadagli Tayfun1

Affiliation:

1. University of Alberta

Abstract

Abstract Capillary imbibition tests are commonly applied to measure wettability alteration potential of chemicals. However, these tests are exhaustive, time-consuming, expensive, and the underlying physics of the alteration process from a surface chemistry point of view is often limited and/or unexplained. Contact angle measurement is a quicker and more feasible screening tool to assess the emerging wettability modifiers. They also provide visual data on the mechanics of the wettability alteration process. This paper focuses on contact angle measurements as a mean to evaluate the wettability alteration on mineral plates and porous rock samples. Imidazolium ionic liquids were tested at different concentrations. To study the effect of pH on the wettability, sodium chloride and sodium borate were used at different concentrations. The composition of divalent ions was varied due to their possible use with low/high salinity water as wettability alteration agent. Unmodified and surface modified silica, zirconium, and alumina nanoparticles were also tested. Contact angle measurements were performed initially on mica, marble, and calcite plates. Experiments were repeated on polished surfaces of Berea sandstone, Indiana limestone, and -cleaned- Grosmont carbonate cores. Oils (pure and solvent mixed crude oils) with different viscosities and densities were used to test the effect of oil type on the process. The images were obtained by an SLR camera at different temperatures ranging from 25 to 80°C. By testing with different concentrations, the optimum chemicals were found for different mineral plates/porous rock systems. Then, the results were cross-checked with the imbibition tests performed on the same samples to validate the contact angle measurement observations. Thermal stability tests were also performed in case of their use during or after a thermal method. For the thermal stability tests, contact angle experiments were conducted in a high pressure and high temperature (up to 200°C) cell. It was shown that certain ionic liquids and nanofluids are stable at high temperatures and can be efficiently used at low concentrations.

Publisher

OTC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3