Laser Aided Ceramic Restoration Removal: A Comprehensive Review

Author:

Ghazanfari Rezvaneh1,Azimi Nahal2,Nokhbatolfoghahaei Hanieh3,Alikhasi Marzieh4

Affiliation:

1. Department of Prosthodontics, School of Dentistry, International Campus, Tehran University of Medical Sciences, Tehran, Iran

2. School of Dentistry, International Campus, Tehran University of Medical Sciences, Tehran, Iran

3. Dental Research Center, Research Institute of Dental Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran

4. Dental Research Center, Laser Research Center of Dentistry, Dental Implant Research center, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran

Abstract

Introduction: All-ceramic restorations are being widely used due to its various advantages. However, they have restricted durability and may have to be removed. The conventional procedure for removal is grinding the restoration with rotary instruments which are considered time-consuming and inconvenient. A newer advantageous method is the application of lasers for debonding ceramics from the tooth surface. The objective of this study is to provide a comprehensive literature review on laser-aided ceramic restorations debonding. Methods: We searched PubMed and Google Scholar databases. Seven articles from 2011 to 2018 were identified. Studies were assessed for the efficacy of laser application and the amount of pulpal temperature rise. Results: Studies selected were categorized according to variables including shear bond strength, debonding time and intrapulpal temperature. Oztoprak and Iseri investigated that erbium-doped yttrium, aluminum, and garnet (Er:YAG) laser application reduced shear bond strength of ceramic laminate veneers. The time of debonding took an average of 190 seconds in Rechmann’s study and 106 seconds in Morford’s study. One of the main issues while using the laser is thermal irritation of the pulp. A 5.5°C temperature increase may cause pulpal damage according to Zach and Cohen. Philips et al and Rechmann et al reported no intrapulpal harm due to temperature increase. Additionally, Phillips et al demonstrated that the laser setting affects both the debonding time and the temperature alterations and that a laser adjustment of 2.5 W/25 Hz would be the best safest group. Conclusion: Removal of ceramic crowns and veneers from tooth surfaces can be successfully done by Er:YAG laser application in a less time-consuming procedure and without any harm to the underlying dentin. However, a temperature rise in the pulp may occur which could be overcome by adequate air water cooling.

Publisher

Maad Rayan Publishing Company

Subject

Urology,Nephrology,Dermatology,Dentistry (miscellaneous),Orthopedics and Sports Medicine,Surgery

Reference24 articles.

1. Comparison of the efficiency and complications of lumenis and wolf morcellators after holmium laser enucleation of the prostate

2. Restoration of esthetics using ceramics laminate veneer; clinical review: a case report;Azzaldeen A;J Adv Med Dent Sci Res,2015

3. The case for moderate” guided prep” indirect porcelain veneers in the anterior dentition The pendulum of porcelain veneer preparations: from almost no-prep to over-prep to no-prep;Magne P;Eur J Esthet Dent,2013

4. Removal of Fractured Laminate Veneers with Er:YAG Laser: Report of Two Cases

5. Effects of different application durations of ER:YAG laser on intrapulpal temperature change during debonding

Cited by 21 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3