Evaluation of the stress generation on the cortical bone and the palatal micro-implant complex during the implant-supported en masse retraction in lingual orthodontic technique using the FEM: Original research

Author:

Shyagali Tarulatha Revanappa1,Aghera Dhaval2

Affiliation:

1. Professor and Head, Department of Orthodontics and Dentofacial Orthopedics, Hitkarini Dental College and Hospital, Jabalpur, India

2. Private practitioner, Rajkot, India

Abstract

Background. This study aimed to evaluate and analyze the distribution of stresses on the palatal micro-implants and the cortical bone at the micro-implant site with optimal orthodontic retraction force in lingual orthodontics. Methods. ANSYS 12.1 software was used to construct the finite element model of the maxillary bone, teeth and the periodontal ligament along with the lingual bracket set-up with wire and the micro-implant. Six- and 8-mm micro-implants were constructed. The final model consisted of 99190 nodes and 324364 elements. A 200-gram of retraction force was applied from the micro-implant to the anterior retraction hook. The micro-implant was embedded between the second premolar and the first molar. Hyper-view software was used to get the results in X-Y-Z dimensions. Results. The maximum von Mises stresses detected were 52.543 MPa for 6-mm micro-implant and 54.489 MPa for 8-mm micro-implant. Maximum stress was at the neck of the micro-implant. The 8-mm implant model showed 6×10-3 mm of lingual displacement. The least displacement of 1×10-3 mm was noticed for both the implant models in the apico-occlusal direction. The maximum von Mises stresses in the cortical bone at the micro-implant site was 18.875 MPa for 6-mm micro-implant and 21.551 MPa for 8-mm micro-implant. Conclusion. Six-mm micro-implant can be the choice for the implant-supported lingual orthodontic retraction as it produced minimal stresses on the cortical bone, and the initial stress displacements produced on the micro-implant were also minimal.

Publisher

Maad Rayan Publishing Company

Subject

General Dentistry

Reference32 articles.

1. Digital lingual orthodontics and temporary anchorage devices for efficient biomechanics

2. Scuzzo G, Takemoto K. Biomechanics and comparative biomechanics. In: Scuzzo G, Takemoto K, Bartelt A. Invisible Orthodontics - Current concepts and solutions in lingual orthodontics. 1st ed. Germany: Quintessenz Verlags- GmbH; 2003. p.556.

3. Effect of intrusive and retraction forces in labial and lingual orthodontics: A finite element study;Mascarenhas R;APOS Trends Orthodontics,2014

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献