Determination of parabens in wastewater and sludge in a municipal wastewater treatment plant using microwaveassisted dispersive liquid-liquid microextraction coupled with gas chromatography-mass spectrometry

Author:

Amin Mohammad Mehdi12ORCID,Hashemi Majid34ORCID,Ebrahimpour Karim12ORCID,Chavoshani Afsane25

Affiliation:

1. Environment Research Center, Research Institute for Primordial Prevention of Non-Communicable Disease, Isfahan University of Medical Sciences, Isfahan, Iran

2. Department of Environmental Health Engineering, School of Health, Isfahan University of Medical Sciences, Isfahan, Iran

3. Environmental Health Engineering Research Center, Kerman University of Medical Sciences, Kerman, Iran

4. Department of Environmental Health Engineering, School of Public Health, Kerman University of Medical Sciences, Kerman, Iran

5. Student Research Committee, Isfahan University of Medical Sciences, Isfahan, Iran

Abstract

Background: Due to the complexities involved in the extraction of micropollutants, the information regarding micropollutants like paraben in wastewater and sludge is scarce. The aim of this study was to adopt a microwave-assisted dispersive liquid-liquid micro-extraction (MADLLME) method for the extraction of parabens in municipal wastewater treatment plant (WWTP). Methods: A mixed stock solution of methyl-, ethyl-, propyl-, and butyl-parabens with concentration of 10 mg/mL were prepared in methanol. To validate this method, the limit of detection (LOD), limit of quantification (LOQ), linearity, and m/z were measured. To adopt this method in different condition, the effect of pH (3, 7, 9, and 12), microwave power (180, 300, 450, and 600 W), solvent type (methanol, acetone, methanol/water, acetone/water), and 1 g folorisil were assessed. After adopting MADLLME method, the paraben fate of this WWTP was evaluated through mass loading and emission. Results: The optimum performance of MADLLME method was observed at pH = 7, microwave power = 450 W, reaction time = 30 s, and methanol as the solvent. The total concentrations of four paraben metabolites in the WWTP ranged between 2505 ng/L in influent, 1953 ng/L in effluent, and 8.03 ng/g at wet weight sludge samples. The total mass loading and emission of four parabens in this WWTP was 0.672 mg/d/1000 people and 0.186 mg/d/1000 people, respectively. Conclusion: MADLLME method seems to be an excellent alternative, as a green extraction technique, for determining various groups of emerging micropollutants in different matrices.

Publisher

Maad Rayan Publishing Company

Subject

Chemical Health and Safety,Public Health, Environmental and Occupational Health,General Environmental Science

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3