Comparison of tracheal tube cuff pressure with two technique: fixed volume and minimal leak test techniques

Author:

Sanaie Sarvin1,Rahmani Farzad2,Chokhachian Sara3,Mahmoodpoor Ata4,Rahimi Panahi Jafar4,Mehdizadeh Esfanjani Robab5,Mirzaei Masomeh2,Soleimanpour Hassan6

Affiliation:

1. Aging Research Institute, Tabriz University of Medical Sciences, Tabriz, Iran

2. Emergency Medicine Research Team, Tabriz University of Medical Sciences, Tabriz, Iran

3. Students’ Research Committee, Tabriz University of Medical Sciences, Tabriz, Iran

4. Anesthesiology Research Team, Tabriz University of Medical Sciences, Tabriz, Iran

5. Neurosciences Research Center, Tabriz University of Medical Sciences, Tabriz, Iran

6. Road Traffic Injury Research Center, Tabriz University of Medical Sciences, Tabriz, Iran

Abstract

Introduction: There is a correlation between endotracheal cuff pressure and airway complication; therefore, cuff pressure measurement is of an essential importance. The gold standard technique is measuring the cuff pressure by a calibrated manometer. However, there are several methods that injects air into balloon pilot and measures the cuff pressure. The aim of this study is to compare the tracheal cuff pressure measurement by two methods: fixed volume and minimal leak test (MLT). Methods: This descriptive study was performed at the emergency department on 110 patients. Patients were randomized into two groups. For one group, fixed volume technique and for the other group MLT was used. Results: Mean cuff pressure was 46.07±23.54 cmH2O in the fixed volume group and 33.72±9.14 cmH2O in the MLT group (P=0.05) which is significantly higher in the fixed volume group (P=0.028). In addition, 56.4% and 78.2% of the subjects had normal cuff pressure in the fixed volume group and MLT group, respectively; indicating a significantly higher rate in MLT group (P=0.025). Conclusion: Both techniques cause above normal intracuff pressure; however, MLT produces more acceptable pressure than fixed volume. It seems that the volume of 10 cc produces high pressures; therefore, fixed values may yield more appropriate results in lower volumes.

Publisher

Maad Rayan Publishing Company

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3