Effect of Column Dimensions on the Punching Shear of Flat Slab

Author:

Faris Hamid Abdulmahdi1,Abd Lubna Mohammed1

Affiliation:

1. Environmental Engineering Department, College of Engineering / Mustansiriyah University, Baghdad, Iraq

Abstract

The "flat slab" is a reinforced concrete slab bolstered, by a number of columns. Punching, shear is a category for collapse for reinforced concrete slabs exposed to great confined forces. In "flat slab" constructions the shear failure happens, at column bolster joints. To avoid this, collapse two methods are used, first method is increasing the column dimensions and, the other is to use drop panel if the first method leads to uneconomical, design. Two examples are used to find the effect, of column dimensions, increase on the punching shear failure of "flat slab". The first example, is a "flat slab" of span (5 by 5) m and the other is of span (6 by 6) m. The column which examined is the interior, edge and corner columns, and the interior column is the most dangerous case. It is concluded that, the increase of column dimensions are lead to avoid of punching shear failure in "flat slab" and the drop panel is enlarge the area of the critical shear perimeter and this avoiding punching shear failure.

Publisher

Technoscience Academy

Subject

General Medicine

Reference9 articles.

1. Sofia, Ericsson, and Kimya, Farahaninia, "Punching Shear in Reinforced Concrete Slabs Supported on Edge Steel Columns", Department of Civil and Environmental Engineering, Division of Structural Engineering, Concrete Structures, CHALMERS UNIVERSITY OF TECHNOLOGYGöteborg, Sweden 2010.

2. Broms, C. E., (1990): Punching of flat plates – a question of concrete properties inbiaxial compression and size effect. ACI Structural Journal, Vol. 87, No. 3, May June 1990, pp. 292-300.

3. Mete A. Sozen and Chester P. Siess, "Investigation of Multiple Panel Reinforced Concrete Floor Slabs: Design Methods- Their Evaluation and Comparison ACI journal, Proceedings, Vol. 60, No. 8, August 1963, pp. 999-1027.

4. Ingvarsson, H. (1977): Betongplattors hållfasthet och armeringsutformning vid hörnpelare (Load-bearing capacity of concrete slabs and arrangement of reinforcement at corner columns). Department of Structural Engineering, The Royal Institute of Technology, Meddelande Nr 122, Stockholm, Sweden, 1977, 143 pp.

5. Hallgren M. (1996): Punching Shear Capacity of Reinforced High Strength Concrete Slabs. Ph.D. Thesis. Department of Structural Engineering, The Royal Institute of Technology, Bulletin 23, Stockholm, Sweden, 1996, 206 pp.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Punching Shear Behavior of HSC Slab–Column Connection Under Cyclic Loading;Transactions of the Indian National Academy of Engineering;2023-11-17

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3