Automatic Placement of Regions of Interest using Distance transform to Measure Spatial Resolution on the Clinical Computed Tomography Images : A Pilot Study

Author:

Ulil A. Taufiq 1,Choirul Anam 1,Eko Hidayanto 1,Ariij Naufal 1

Affiliation:

1. Departement of Physics, Faculty of Science and Mathematics, Diponegoro University, Jl. Prof. Soedarto SH, Tembalang, Semarang 50275, Central Java, Indonesia

Abstract

We propose a new algorithm called distance transform region of interest (DT-ROI) to deal with the irregular patient's surface. The ROIs can be placed orthogonally along the patient’s surface to get spatial resolution. The algorithm was developed using several image processing techniques. The original image was first segmented to obtain a segmented image. The segmented image was eroded and dilated to obtain an eroded and dilated image. Both the eroded and dilated images were edge detected to obtain the edge images of the eroded and dilated image. The edge images were distance transformed to obtain the closest pixel coordinate. Finally, ROIs were placed based on the coordinates obtained before. The DT-ROI was then assessed qualitatively by comparison with the ROI placement from the standard radial ROI (SR-ROI) on a Polymethyl methacrylate (PMMA) phantom, an anthropomorphic phantom, and the patient’s computed tomography images. The algorithm resulted in orthogonalized ROIs, both along the irregular object and the circular object. The ROI comparison between DT-ROI and SR-ROI shows a little difference in terms of orthogonality on PMMA phantom. Meanwhile, on the anthropomorphic phantom and the patient’s CT image, the DT-ROI produced a lot more orthogonal ROIs than the SR-ROI. Several ROIs of the DT-ROI have decreased orthogonality at certain sections, which can be observed in both phantom and patient images. However, theoretically, a slight decrease in orthogonality will not affect the modulation transfer function (MTF) measurement significantly. The DT-ROI algorithm has been successfully developed based on distance transformation and performed as the design. The algorithm can automatically place ROIs along the patient’s irregular surface better than the SR-ROI algorithm. However, not all ROIs placed from DT-ROI are well-orthogonalized. DT-ROI still needs to be improved before it is used to measure MTF to obtain a more optimal measurement.

Publisher

Technoscience Academy

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3