Comparison of Water-Equivalent Diameter Measured from CT Localizer Radiograph Based on Two phantoms of the Step-Wedge and Computed Tomography Dose Index

Author:

Sitti M. Rif’ah 1,Choirul Anam 1,Heri Sutanto 1,Heryani Cholid 2

Affiliation:

1. Department of Physics, Faculty of Science and Mathematics, Diponegoro University, Jl. Prof. Soedarto SH, Tembalang, Semarang 50275, Central Java, Indonesia.

2. Installation of Radiology, Rumah Sakit Umum Daerah (RSUD) Kraton Pekalongan, Jl.Veteran No. 31, Padukuhan Kraton, Pekalongan City, 51116, Central Java , Indonesia

Abstract

The purpose of this study is to compare the water-equivalent diameter (Dw) and size-specific dose estimate (SSDE) obtained from CT localizer radiograph based on the step-wedge and computed tomography dose index (CTDI) phantoms. The two phantoms were scanned using a 64-slice SIEMENS Somatom CT Scanner with tube currents of 100 mA and 120 kV. The CT localizer radiographs of two phantoms were obtained. Subsequently, relationships between pixel values (PV) and water-equivalent thickness (tw) were developed. Based on those relationships, the Dw and SSDE of twenty patients were calculated from the CT localizer radiographs. The results of the Dw and SSDE measured using CT localizer radiographs based on the two phantoms were compared. The relationships between PV and tw obtained from both CT localizer radiographs of the phantoms of step-wedge and CTDI are established. The Dw and SSDE values from the CT localizer radiograph calibrated with the CTDI phantom and step-wedge phantom also have linear relationship with R2 > 0.99. The statistical test value with p-value > 0.05 indicating that the two measurements of Dw and SSDE based on two phantoms are not statistically different. The results from the step-wedge phantom are comparable with those from the CTDI phantom. The relationship PV and tw with CT localizer radiograph from the step-wedge phantom can produce accurate calibration results. The results of the calibration of the step-wedge phantom can then determine the value of Dw and SSDE.

Publisher

Technoscience Academy

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Evaluation of Tube Current Modulation Profile on CT Image of 128 slices CT Scanner using The Borobudur Phantom;International Journal of Scientific Research in Science and Technology;2023-09-10

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3