Measurement of Renal Dimensions to Determine Standard Reference Renal Volume Model for Clinical Application in Ghana

Author:

Shirazu Issahaku1,Mensah Y. B.2,Schandorf Cyril3

Affiliation:

1. University of Cape Coast, School of Agriculture and Physical Sciences Faculty of Physical Sciences, Department of Physics, Cape coast, Ghana

2. University of Ghana Medical School, Department of Radiology, Korle-Bu Teaching Hospital, Accra Ghana

3. Graduate School of Nuclear and Allied Sciences, University of Ghana, Legon, Ghana

Abstract

The study is based on measurements of renal dimensions to determine standard reference renal volume model and renal volumetric ellipsoid coefficient. Two methods, Voxel count method and rotational renal ellipsoid equation were the two measuring tools used with an integrated MVL application software platform. The procedure involve measurement of linear dimensions together with using the snake technique to draw the region of interest (ROI) for the volumetric measurements. These were done to obtain: renal length, lateral diameter, A-P diameter and the total number of voxels to estimates the renal volume. These parameters were used to calculate renal volume using the rotational renal ellipsoid equation as well as using the Minitab statistical software to model renal volume equation. The reference standard renal volume was also determined using water displacement with the Archimedes' principle. The average renal shape index and its dispersion (i.e. covariance matrix) was approximately 1±0.02. The male average measured values for right and left kidneys were as follows: renal length, 103.35cm and 105.13cm, lateral diameter, 60.79 and 60.40 and A-P diameter, 44.12 and 44.95 and renal volume; 146.74cm3 and 151.76cm3 respectively. Furthermore, the female average measured values for right and left kidneys were as follows: renal length, 101.43 and 102.98, lateral diameter, 59.20 and 59.02 and A-P diameter, 43.09 and 44.82, renal volume 142.04cm3 and 148.29cm3 respectively. The average estimated renal volumetric ellipsoid coefficient (VeC) was 0.53. However, various variations for both male and female, with their corresponding right and left kidneys were, 0.5283, 0.5297, 0.5280 and 0.5304 respectively. The reference renal dimensions including the standard renal volume and renal volumetric ellipsoid coefficient are recommended for clinical application in Ghana.

Publisher

Technoscience Academy

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3