Design and Fabrication of Water Phantom for Treatment Verification in High Dose Rate (HDR) Brachytherapy of the Cervix

Author:

Avevor Justice1,Amoako Joseph2,Amoako George1,Tagoe Samuel Nii3

Affiliation:

1. University of Cape Coast, School of Agriculture and Physical Sciences Faculty of Physical Sciences, Department of Physics, Cape coast, Ghana

2. Ghana Atomic Energy Commission, Radiation Protection Institute, Accra, Ghana

3. National Centre for Radiotherapy and Nuclear Medicine, Accra, Ghana

Abstract

The aim of this study is to design and fabricate a local anatomical water phantom for dose distribution measurements during high dose rate brachytherapy of the cervix. Phantoms for dosimetry are used when there is a need to simulate the conditions of a procedure to measure dose at certain points of interest. It is dangerous to place a human being in a beam for dose measurements. Perspex (PMMA) sheets of thickness 6mm and 10mm were used for fabricating the phantom. The phantom designed is curved in shape with a predominantly 6mm thickness of the perspex material. It has a height of 41cm and breadth 31cm. The pieces of perspex material were glued to each other using Trichloromethane (chloroform) at room temperature. It is an organic compound with the formula CHCI3. A perspex sheet of 10mm was used to make one end of the phantom thicker than the other. This was done to support the reconstruction box. Two thin film holder slabs of dimensions 31.5 ×2.8 ?cm?^2 were fabricated by joining two sheets of 6 mm perspex together with the chloroform. A small cavity of 2.8 × 2.5 cm2 was created in the slab to represent the bladder and the rectum (organs at risk). These same cavities are meant to hold the detectors (films) in place for the measurement of dose to the organs at risk. The film holders with the cavities were then positioned vertically, but anterior and posterior to each other. Another holder, rectangular in shape was fabricated to hold the film holders. This holder was made from perspex sheets of thickness 6mm and 10mm with dimensions of 6.8 × 6.8 cm2. This is to allow for the distances between the bladder and the rectum to be varied during the dose measurements. It must be noted that the anatomical distance between the bladder and the rectum which are posterior and anterior to the cervix vary from patients to patients. Special clamping devices were fabricated to hold the applicators in a firm position during the intracavitary brachytherapy insertions. These special clamps were made by joining perspex of 10mm thickness in a cuboid shape; a hole was drilled in them to enable a plastic screw to lock the applicators.The relative electron density of the phantom designed was determined to be 1.069 which is comparable to water. This makes the phantom suitable for dose distribution measurements.

Publisher

Technoscience Academy

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3