Test–Retest Reliability of the Total Motion Release® Scale

Author:

Miley Emilie N.,Reeves Ashley J.,Casanova Madeline P.,Martonick Nickolai J.P.,Baker Jayme,Baker Russell T.

Abstract

Context: Total Motion Release® (TMR®) is a novel treatment paradigm used to restore asymmetries in the body (eg, pain, tightness, limited range of motion). Six primary movements, known as the Fab 6, are performed by the patient and scored using a 0 to 100 scale. Clinicians currently utilize the TMR® scale to modify treatment, assess patient progress, and measure treatment effectiveness; however, the reliability of the TMR® scale has not been determined. It is imperative to assess scale reliability and establish minimal detectable change (MDC) values to guide clinical practice. Objective: To assess the reliability of the TMR® scale and establish MDC values for each motion in healthy individuals in a group setting. Design: Retrospective analysis of group TMR® assessments. Setting: University classroom. Participants: A convenience sample of 61 students (23 males and 38 females; 25.48 [5.73] y), with (n = 31) and without (n = 30) previous exposure to TMR®. Intervention: The TMR® Fab 6 movements were tested at 2 time points, 2 hours apart. A clinician with previous training in TMR® led participant groups through both sessions while participants recorded individual motion scores using the 0 to 100 TMR® scale. Test–retest reliability was calculated using an intraclass correlation coefficient (2,1) for inexperienced, experienced, and combined student groups. Standard error of measurement and MDC values were also assessed for each intraclass correlation coefficient. Outcome Measure: Self-reported scores on the TMR® scale. Results: Test–retest reliability ranged from 0.57 to 0.95 across the Fab 6 movements, standard error of measurement values ranged from 4.85 to 11.77, and MDC values ranged from 13.45 to 32.62. Conclusion: The results indicate moderate to excellent reliability across the Fab 6 movements and a range of MDC values. Although this study is the first step in assessing the reliability of the TMR® scale for clinical practice, caution is warranted until further research is completed to establish reliability and MDC values of the TMR® scale in various settings to better guide patient care.

Publisher

Human Kinetics

Subject

Rehabilitation,Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine,Biophysics

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3