Sweating Rate and Sweat Chloride Concentration of Elite Male Basketball Players Measured With a Wearable Microfluidic Device Versus the Standard Absorbent Patch Method

Author:

Baker Lindsay B.1,King Michelle A.1,Keyes David M.1,Brown Shyretha D.1,Engel Megan D.1,Seib Melissa S.2,Aranyosi Alexander J.23,Ghaffari Roozbeh234

Affiliation:

1. Gatorade Sports Science Institute, PepsiCo R&D, Barrington, IL, USA

2. Epicore Biosystems, Inc., Cambridge, MA, USA

3. Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL, USA

4. Department of Biomedical Engineering, Northwestern University, Evanston, IL, USA

Abstract

The purpose of this study was to compare a wearable microfluidic device and standard absorbent patch in measuring local sweating rate (LSR) and sweat chloride concentration ([Cl]) in elite basketball players. Participants were 53 male basketball players (25 ± 3 years, 92.2 ± 10.4 kg) in the National Basketball Association’s development league. Players were tested during a moderate-intensity, coach-led practice (98 ± 30 min, 21.0 ± 1.2 °C). From the right ventral forearm, sweat was collected using an absorbent patch (3M Tegaderm + Pad). Subsequently, LSR and local sweat [Cl] were determined via gravimetry and ion chromatography. From the left ventral forearm, LSR and local sweat [Cl] were measured using a wearable microfluidic device and associated smartphone application-based algorithms. Whole-body sweating rate (WBSR) was determined from pre- to postexercise change in body mass corrected for fluid/food intake (ad libitum), urine loss, and estimated respiratory water and metabolic mass loss. The WBSR values predicted by the algorithms in the smartphone application were also recorded. There were no differences between the absorbent patch and microfluidic patch for LSR (1.25 ± 0.91 mg·cm−2·min−1 vs. 1.14 ±0.78 mg·cm−2·min−1, p = .34) or local sweat [Cl] (30.6 ± 17.3 mmol/L vs. 29.6 ± 19.4 mmol/L, p = .55). There was no difference between measured and predicted WBSR (0.97 ± 0.41 L/hr vs. 0.89 ± 0.35 L/hr, p = .22; 95% limits of agreement = 0.61 L/hr). The wearable microfluidic device provides similar LSR, local sweat [Cl], and WBSR results compared with standard field-based methods in elite male basketball players during moderate-intensity practices.

Publisher

Human Kinetics

Subject

Nutrition and Dietetics,Orthopedics and Sports Medicine,General Medicine,Medicine (miscellaneous)

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3