Assessing the Accuracy of Activity Classification Using Thigh-Worn Accelerometry: A Validation Study of ActiPASS in School-Aged Children

Author:

Lendt Claas12ORCID,Hettiarachchi Pasan3ORCID,Johansson Peter J.34ORCID,Duncan Scott1ORCID,Lund Rasmussen Charlotte5ORCID,Narayanan Anantha1ORCID,Stewart Tom1ORCID

Affiliation:

1. Human Potential Centre, School of Sport and Recreation, Auckland University of Technology, Auckland, New Zealand

2. Institute for Movement Therapy and Movement-Oriented Prevention and Rehabilitation, German Sport University Cologne, Cologne, Germany

3. Occupational and Environmental Medicine, Department of Medical Sciences, Uppsala University, Uppsala, Sweden

4. Occupational and Environmental Medicine, Uppsala University Hospital, Uppsala, Sweden

5. School of Allied Health, Curtin University, Perth, Australia

Abstract

Background: The ActiPASS software was developed from the open-source Acti4 activity classification algorithm for thigh-worn accelerometry. However, the original algorithm has not been validated in children or compared with a child-specific set of algorithm thresholds. This study aims to evaluate the accuracy of ActiPASS in classifying activity types in children using 2 published sets of Acti4 thresholds. Methods: Laboratory and free-living data from 2 previous studies were used. The laboratory condition included 41 school-aged children (11.0 [4.8] y; 46.5% male), and the free-living condition included 15 children (10.0 [2.6] y; 66.6% male). Participants wore a single accelerometer on the dominant thigh, and annotated video recordings were used as a reference. Postures and activity types were classified with ActiPASS using the original adult thresholds and a child-specific set of thresholds. Results: Using the original adult thresholds, the mean balanced accuracy (95% CI) for the laboratory condition ranged from 0.62 (0.56–0.67) for lying to 0.97 (0.94–0.99) for running. For the free-living condition, accuracy ranged from 0.61 (0.48–0.75) for lying to 0.96 (0.92–0.99) for cycling. Mean balanced accuracy for overall sedentary behavior (sitting and lying) was ≥0.97 (0.95–0.99) across all thresholds and conditions. No meaningful differences were found between the 2 sets of thresholds, except for superior balanced accuracy of the adult thresholds for walking under laboratory conditions. Conclusions: The results indicate that ActiPASS can accurately classify different basic types of physical activity and sedentary behavior in children using thigh-worn accelerometer data.

Publisher

Human Kinetics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3